English
Language : 

FDF-4C-750 Datasheet, PDF (1/2 Pages) Merrimac Industries, Inc. – FREQUENCY DOUBLERS
FD Series
FREQUENCY DOUBLERS
5to3000M Hz/M inimum SpuriousOutput/FlatpackorTO-5orSM A Connectors
Model
Number
Input
Freq.,
MHz
PRINCIPAL SPECIFICATIONS
Operating
†Conversion
Input Frequency, Loss, dB,
MHz
Typ. Max.
*Typical Harmonic Output
F1
F3
F4
dB dB dB
RF Input
Range Package
(Nom.) Style
FDF-4C-750 75 - 1500
75 - 300
300 - 700
700 - 1500
11 14
11 14
11 14
– 50 – 50
– 40 – 45
– 35 – 40
+7 to 16 Flat
(13 dBm)
FDF-500A
5 - 500
5 - 100
100 - 300
300 - 500
12 16
12 15
15 17
– 40 – 45 – 25
– 30 – 40 – 27
– 30 – 40 – 30
+5 to 18 Flat
(13 dBm)
FDF-4A-1500 25 - 3000
25 - 600
600 - 2500
2500 - 3000
12 14
12 13
13 15.5
–27 –30
–18 –30
–15 –20
+7 to 16 Flat
(13 dBm)
FDM-500A
5 - 500
5 - 100
100 - 300
300 - 500
12 16
12 15
15 17
– 40 – 45 – 25
– 35 – 40 – 27
– 30 – 40 – 30
+5 to 18 SMA
(13 dBm)
FDT-500A
5 - 500
5 - 100
100 - 300
300 - 500
10 13
10 13
11 15
– 40 – 45 – 25
– 35 – 40 – 27
– 30 – 40 – 30
+2 to 13
(9 dBm)
†Conversion Loss measured at nominal Input Power
*Typical Harmonic Level is referenced to RF Input Power
All specifications measured at nominal input power and referenced to input power.
TO-5
Typical FDM-500A Performance
GENERAL SPECIFICATIONS
Impedance:
50 Ω nom.
Weight, FDM-500A
0.65 oz. (2.5 g)
Weight, All others:
0.09 oz. (18 g)
Operating Temperature: – 55° to +85°C
General Notes:
1. Merrimac Frequency Doublers cover
the frequency range of 5 to 3000 MHz
using lumped element circuits for broad
bandwidth and excellent rejection of
fundamental and third harmonic energy.
These units may also act as quadruplers
with additional conversion loss.
2. Merrimac Frequency Doublers comply
with the relevant sections of MIL-M-28837
and may be supplied screened for
compliance with additional specifications
for military and space specifications
requiring the highest reliability.
23Feb96
ForfurtherinformationcontactM ERRIM AC /41 FairfieldPl.,W estCaldw ell,NJ,07006 /973-575-1300 /FAX 973-575-0531