English
Language : 

MB64 Datasheet, PDF (3/5 Pages) MERITEK ELECTRONICS CORPORATION – structure graphics compliant to surge standard test system
/RZ&DSDFLWDQFH
6XSHU/RZ&ODPSLQJ9ROWDJH
7UDQVLHQW9ROWDJH6XSSUHVVRUV
V-I CHARACTERISTICS
MB6A Series
MERITEK
CLAMPING ABILITY
Compare 0%$ and TSS P0080SX surge test, which is compliant with ITU K21 10/700μs 6KV
lightning surge. Here are the results:
PART 10/700μs 6KV lightning
NUMBER
surge wave
Clamping Voltage
Wave
Result
0%$
Very low clamping
voltage 13.2V,
excellent clamping
ability
P0080SX
Clamping voltage up
to 82V, if the
protected circuit’s
withstanding voltage
is not enough, the
protected chip is easy
to be damaged
3
Rev 7