English
Language : 

TH8065 Datasheet, PDF (7/40 Pages) Melexis Microelectronic Systems – Voltage Regulator with LIN Transceiver and Watchdog
TH8065
Voltage Regulator with LIN Transceiver and Watchdog
Parameter
Reset threshold - POR
Reset threshold – low voltage reset
Vres Hysteresis
VRESHYS = |VRES(ON) – VRES(OFF)|
Master reset threshold
Input voltage low
Input voltage high
Hysteresis
Pull-down resistor EN low
Pull-down current EN high
Output voltage low
Pull-up current
Input threshold low
Input threshold high
Pull up current (charge current)
Pull down current (discharge current)
Pull down resistor
Input voltage low
Input voltage high
Thermal shutdown
Thermal recovery
Symbol
VRES(ON)
VRES(OFF)
Condition
VCC ramp up, t > trr
VCC ramp down, t > trr
VRESHYS
VMRES
Enable Input EN
VENL
VENH
VENHYS
RpdENL
IpdENH
0V ≤ VEN ≤ 0.8V
VEN ≥ VENL
Output RESET
VOL1_RESET IOUT = 1 mA, VSUP ≥ 6 V
Ipu
Input CWD
VCWDL
VCWDH
ICWD_pu
ICWD_pd
VIN = 1V
VIN = 1V
Input WDI
Rpd_WDI
VIL_WDI
VIH_WDI
VIN = VCC
Thermal Protection
TJSHD
TJREC
Min
Typ
Max Unit T[1]
4.4
4.6
4.8 V A
4.4
4.6
4.8 V A
150 mV A
3.0
3.15
3.3 V D
-0.3
0.8 V A
2.0
VSUP +0.3 V A
50
300 mV A
14
25
35 kΩ A
0.5
2
10 µA A
0.8 V A
-500
-375
-250 μA A
0.076
0.08
0.084 VCC A
0.342
0.36
0.378 VCC A
7.6
13.9
20.2 µA A
0.76
1.39
2.02 µA A
35
50
73 kΩ A
0.3 VCC A
0.7
VCC A
155
180 °C D
126
°C D
[1] A = 100% serial test, B = Operating parameter, C = Only used for data characterization (cpk), D = Value guaranteed by design
[2] No active watchdog reset
[3] The nominal VCC voltage is measured at VSUP =12V. If the VCC voltage is 100mV below its nominal value then the voltage drop is
VD = VSUP – VCC.
TH8065 – Datasheet
3901008065
Page 7 of 40
May 2006
Rev 003