English
Language : 

MLX92292 Datasheet, PDF (5/11 Pages) Melexis Microelectronic Systems – μ-Power Programmable ASIL B capable Hall Effect Switch/Latch
MLX92292
µ-Power Programmable ASIL B capable
Hall Effect Switch/Latch
3 Magnetic Specifications – Normal (vertical) Sensitive Version
DC Operating Parameters VDD = 3.3V to 18V, TA = -40°C to 150°C (unless otherwise specified)
Parameter
Symbol Test Conditions
Min
Typ(2)
Max
Operating Point programming range(2)
BOP
VDD =12V, TA =25°C
-90
─
90
Release Point programming range(2)
BRP
VDD =12V, TA =25°C
-90
─
90
Operating Point magnitude programming(3, 4) BOP
─
12
─
Release Point magnitude programming(3, 4) BRP
─
12
─
Operating Point polarity selection
BOP
─
1
─
Release Point polarity selection
BRP
─
1
─
Direct or inverted output selection
─
1
─
Factory pre-programmed Operating Point,
Latch
BOP
VDD =12V, TA =25°C,
programming target 28mT
26
28
30
Factory pre-programmed Release Point,
Latch
BRP
VDD =12V, TA =25°C,
programming target -28mT
-26
-28
-30
Temperature Coefficient programming
range(5, 6)
TC
VDD =12V, Latch with
BOP =28mT, BRP = -28mT
-2400
0
Temperature Coefficient selection
─
5
─
Units
mT
mT
bit
bit
bit
bit
bit
mT
mT
ppm/ºC
bit
Notes:
1. Unless otherwise specified the typical values are defined at TA = +25ºC and VDD = 12V
2. Guaranteed by correlation with production test at B=28mT and verified by characterization
3. The programming step is <0.5% of the programmed BOP value for |BOP| ≥ 6mT and <0.02mT for |BOP| ≤ 6mT at TA = +25ºC
4. Programming of very low hysteresis magnitude (BOP – BRP < 1mT) could lead to output toggling due to noise and mechanical looseness
in the magnetic system.
5. TC target values
6. The Temperature Coefficient is calculated using the following formula:
TC

(BOPTA2  BRPTA2 )  (BOPTA1
(BOPTA1  BRPTA1) * (TA2
 BRPTA1
 TA1)
)
*106
,
p
p
m/o
C;
TA1

25o C; TA2
 150o C
The factory pre-programmed target TC value is 0ppm/ºC.
µ-Power Programmable ASIL B Hall S/L
Rev. 1.1
Page 5 of 11
Abstract
Sept 11, 2015