5 Magnetic Specifications
DC Operating Parameters VDD = 3.5 to 24V, TJ = -40°C to 165°C (unless otherwise specified)
Magnetic &
Temperature
Coefficient Option
Code Combination
Test Conditions
Operating Point
BOP (mT)
Min Typ Max
Release Point
BRP (mT)
Min Typ Max
Temperature
Coefficient
(ppm/oC)
Typ
High Sensitivity +
NdFeB TC match
TJ = -40°C
TJ = 25°C
TJ = 150°C
5.9 8.5 10.9 3.5 5.5 7.9
6.1 7.9 9.5 3.9 5.3 7.0
3.8 6.8 9.6 2.7 5.0 8.2
-1100
Table 1: Magnetic Switching Points & Temperature Coefficient combination
Temperature coefficient is calculated using the following formula:
BOPT 2
BOP25o C
BOPT 1
T2 T1
*106 , ppm / o C;T1
25o C;T2
150o C
6 Magnetic Behaviour
6.1 Unipolar Switch sensor
Parameter
Option 1
Pole Active
South
Current level
IDD = ION
Magnetic Polarity
Direct
IDD = IOFF
0mT
BRP
BOP
Flux density
Fig.1 – Direct South Pole Active
390109224106 Rev. 1
Page 5 of 11
March/12