5. MLX90254 Electrical Specifications
DC Operating Parameters TA = -40oC to 150oC, VDD = 4V to 24V (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min Typ Max Units
Supply Voltage
Vs
4 12 24
V
Supply Current (1)
Is
5 8.5 12 mA
Output Voltage
Vout
Output state: OFF
24
V
Output DC Current
Iout
Vout < 1V
25 mA
Output Saturation Voltage Vsat
Output state: ON
Iout=25 mA
500 mV
Output Short-Circuit Current Iscprot
Output state: ON
Vout > 2V
10 45 70 mA
Output Leakage Current Ileak
Output state: OFF
10
µA
Output Rise Time
Tr
Vout = 12 V
0.1
µs
Rpull-up = 600 Ω
No Load Capacitor
Output Fall Time
Tf
Vout = 4.5 .. 24 V
Cload = 1 nF
0.5
µs
Startup Time (2)
Rpull-up = 1 kΩ
Tpower-on
150 ms
Frequency (3)
f
15
30000 Hz
Supply Rise Time
Tsr
Vs = 0 .. 24 V
100
ns
(1) Supply current can rise-up to 20 mA max. in the 3-4 volts Vdd range.
(2) Start-up time : when the wheel has started spinning, the output signal appears after a few teeth but a
delay up to 150 ms could be seen before the highest accuracy/repeatability.
(3) The frequency is linked with the first order high pass filter with a cut-off frequency smaller than 20 Hz.
3901090254
Rev. 005
Page 4 of 9
Datasheet
Jun/04