English
Language : 

MLX90247 Datasheet, PDF (4/9 Pages) List of Unclassifed Manufacturers – Discrete Infrared Thermopile Detectors
MLX90247 family
Discrete Infrared Thermopile Detectors
5. MLX90247 Specifications
Operating temperature range: Ta = -40 to 85 ˚C unless otherwise noted
P a ra m e te r
Se ns i t i v e A r e a
W a v e l e ng t h r a ng e
D C m e m b r a ne r e s p o ns i t i v i t y
Se ns i t i v i t y ( A l p h a )
T h e rm o p ile o u tp u t v o lta g e
W i nd o w a p e r t u r e s i z e
F ie ld o f v ie w
Sp e c t r a l s e ns i t i v i t y
T h e r m o p i l e R e s i s t a nc e
N o is e
NEP
T i m e c o ns t a nt
T h e r m o p i l e r e s i s t a nc e t e m p c o
P T C v a l u e R ( 25 ° C)
P T C T C1
P T C T C2
W i t h s t a nd E SD v o l t a g e
T y p ic a l
1. 2 x 1. 2
5 . 5 … 15
12
4. 28 ±25 % x 10-13
46 ±25 %
3. 5
88
> 70
<1
60
32
2. 6
30
0. 1
24 ±3 0 %
6 5 00 ±20 %
16
+ 8 00
- 7 000
U n it s
mm2
µm
V/W
V/K4
µV
mm
D eg
%
%
kΩ
nV / √H z
nW / √H z
ms
%/˚C
kΩ
p p m /˚ C
p p m /˚ C2
V
V
C o n d it io n
T a = 25 ˚ C T b b = 6 0˚ C
F u ll F O V
T a = 26 ˚ C T b b = 27 ˚ C, F u l l F O V
5 0% t h e r m o p i l e s i g na l
7 . 5 µ m < λ < 13. 5 µ m
0< λ < 5 µ m
T a = 25 ˚ C
R MS, T a = 25 ˚ C
R MS, T a = 25 ˚ C
T a = 25 ˚ C
NOTE: The thermistor resistance can be calculated using following expresion:
[ ] R(T ) = R(25o C) 1 + TC1(T − 25oC) + TC2 (T − 25oC)2
Thermopile output voltage is:
Vir = Alpha .[ (To4) – (Ta4) ]
where To is the measured object temperature, both To and Ta are in Kelvins
Note: When measuring resistances with an ohm meter, please take care that the internal protection
diodes, as indicated in the functional diagram below, are always reverse biased.
3901090247
Rev. 004
Page 4 of 9
Data Sheet
Oct/07