4 Absolute Maximum Ratings
Parameter
Symbol
Supply Voltage (operating)
VDD
Supply Current
IDD
Output Voltage
VOUT
Output Current
IOUT
Operating Temperature Range
TA
Storage Temperature Range
TS
ESD Sensitivity (1)
-
Table 1: Absolute maximum ratings
Value
5
5
5
5
-40 to 85
-50 to 150
5000
Units
V
mA
V
mA
°C
°C
V
Note 1: Human Body Model according JESD22-A114 standard – 100pF capacitor discharged through 1.5kΩ resistor into each pin.
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-maximum-
rated conditions for extended periods may affect device reliability.
5 Pin Definitions and Descriptions
SE Package
Pin Name
Function
Pin № (SE)
VDD
Power Supply
1
GND
Ground
3
OUT
Output (Open Drain) 2
NC
Not Connected
-
Table 2: Pin definitions and descriptions
Pin № (LD)
2
3,4
5
1,6
Note : Exposed Pad on LD package is connected to ground