EVB90614 Datasheet, PDF (22/52 Pages) Melexis Microelectronic Systems – Single and Dual Zone Infra Red Thermometer in TO-39
MLX90614 family
Single and Dual Zone
Infra Red Thermometer in TO-39
8.5.1 Single PWM format
In single PWM output mode the settings for PWM1 data only are used. The temperature reading can be
calculated from the signal timing as:
TOUT
2t2
T
TO _ MAX
TO _ MIN
TO _ MIN
where Tmin and Tmax are the corresponding rescale coefficients in EEPROM for the selected temperature
output (Ta, object temperature range is valid for both Tobj1 and Tobj2 as specified in the previous table) and T
is the PWM period. Tout is TO1, TO2 or Ta according to Config Register [5:4] settings.
The different time intervals t1…t4 have following meaning:
t1: Start buffer. During this time the signal is always high. t1 = 0.125s x T (where T is the PWM period,
please refer to Figure 14).
t2: Valid Data Output Band, 0…1/2T. PWM output data resolution is 10 bit.
t3: Error band – information for fatal error in EEPROM (double error detected, not correctable).
t3 = 0.25s x T. Therefore a PWM pulse train with a duty cycle of 0.875 will indicate a fatal error in EEPROM (for
single PWM format). FE means Fatal Error.
Example:
Figure 15: PWM example single mode
TO _ MIN 0 C TO _ MIN EEPROM ,0x01 100 TO _ MIN 273.15 27315d 0x6 AB3
TO _ MAX 50 C TO _ MAX EEPROM ,0x00 100 TO _ MAX 273.15 32315d 0x7E3B
Captured PWM period is T = 1004 s
Captured high duration is t = 392 s
Calculated duty cycle is:
D t 392 0.3904 or 39.04%
T 1004
The temperature is calculated as follows:
TO 2 0.3904 0.125 50 0 0 2 0.2654 50 26.54 C