5.4 Test points and patch area
Some analogue outputs are foreseen on the evaluation board as test pins referenced from TP1 to TP4. These
test pins can be used to monitor signals. In order to connect other sensors to the MLX90129, a patch area is
available. The following table describes all test pins available and the following schematic shows the signals
available on the patch area.
Test pins number
TP1
TP2
TP3
TP4
Name
Coil1
Coil2
NC
GND
Description
Coil 1 pin
Coil 2 pin
Not used
Ground
SENSSUP1
SENSSUP2
SENS1
SENS2
SENS3
SENS4
VREG
CON5
1
2
3
4
5
6
7
8
6 Using the EVB90129
Patch area
GND
The EVB90129 can be configured and controlled through its RFID and its SPI interface. Please refer to the
MLX90129 Datasheet and the application notes for information about register configuration and command
description. A bad configuration can lock the MLX90129 communication completely. Care should be taken
about the command sent and the configuration applied. In order to avoid bad manipulation and to speed up the
development, the MLX90129 development kit is available (DVK90129). It contains the EVB90129, a USB RFID
reader and user friendly software interface. Please refer to our website (www.melexis.com) for more
information.
7 Schematic
Schematic of the MLX90129 evaluation board:
390129012901
Rev 003
Page 11 of 13
Evaluation Board
June-2010