English
Language : 

MK5-1A66C-500W Datasheet, PDF (3/4 Pages) Meder Electronic – Reed Sensors with Screw Fastening Slot
MK05 Series
Reed Sensors
with Screw Fastening Slot
MEDER electronic
CONTACT DATA
All Data at 20° C
Contact Ratings
Switch Model →
Contact Form →
Switch 66
Form A
Conditions
Min. Typ. Max. Units
Switching Power
Switching Voltage
Any DC combination of V & A not
to exceed their individual max.‘s
DC or peak AC
10
W
200
V
Switching Current
Carry Current
DC or peak AC
DC or peak AC
0.5
A
1.25
A
Static Contact Resistance w/ 0.5 V & 10mA
Dynamic Contact Resistance
Measured w/ 0.5 V & 50mA ,
1.5 ms after closure
Insulation Resistance across
Contacts
100 volts applied
Breakdown Voltage across
Contact
Voltage applied for 60 sec. min.
Operate Time incl. Bounce Measured w/ 100 % overdrive
1010*
225 *
150 mΩ
200 mΩ
Ω
VDC
0.5
ms
Release Time
Measured w/ no coil suppression
0.1
ms
Capacitance
at 10 kHz cross contact
0.2
pF
Contact Operation **
Must Operate Condition
Steady state field
10
60
AT
Must Release Condition
Steady state field
4
54
AT
Environmental Data
Shock Resistance
1/2 sinus wave duration 11 ms
50
g
Vibration Resistance
From 10 - 2000 Hz
20
g
Ambient Temperature
10°C/ minute max. allowable
-20
85
oC
Stock Temperature
10°C/ minute max. allowable
-35
85
oC
Soldering Temperature
5 sec.
260
oC
Please note: The indicated electrical data are maximum values and can vary downwards when using
a more sensitive switch.
* Insulation resistance of 1012 and breakdown voltage of 480 VDC is available.
** These ranges refer to the uncut / unmodified Reed Switches described in our Reed Switch section.
Consult factory if more detail is required.
www.meder.com
224