English
Language : 

PSND200E06 Datasheet, PDF (1/1 Pages) Meder Electronic – Fast Recovery Epitaxial Diode Module
Fast Recovery
Epitaxial Diode
(FRED) Module
PSND 200E
IFAV
VRRM
= 408 A
= 200-600V
Preliminary Data Sheet
VRSM
V
200
400
600
VRRM
V
200
400
600
Type
PSND 200E/02
PSND 200E/04
PSND 200E/06
Symbol
IFAV
IFSM
∫ i2 dt
TVJ
TVJM
Tstg
VISOL
Md
Weight
Test Conditions
TC = 70°C
TVJ = 45°C
VR = 0
t = 10 ms
t = 8.3 ms
TVJ = TVJM
VR = 0
t = 10 ms
t = 8.3 ms
TVJ = 45°C
VR = 0
t = 10 ms
t = 8.3 ms
TVJ = TVJM
VR = 0
t = 10 ms
t = 8.3 ms
50/60 HZ, RMS t = 1 min
IISOL ≤ 1 mA
t=1s
Mounting torque
Terminal connection torque
typ.
(50 Hz), sine
(60 Hz), sine
(50 Hz), sine
(60 Hz), sine
(50 Hz), sine
(60 Hz), sine
(50 Hz), sine
(60 Hz), sine
(M6)
(M6)
Maximum Ratings
408
A
4000
A
4400
A
3600
A
3900
A
80000
A2 s
80300
A2 s
64800
A2 s
63100
A2 s
-40 ... + 150
°C
150
°C
-40 ... + 125
°C
2500
V∼
3000
V∼
5
Nm
5
Nm
270
g
Symbol
IR
VF
trr
VTO
rT
RthJC
RthJH
dS
dA
a
Test Conditions
VR = VRRM
VR = VRRM
IF = 200 A
TVJ = 25°C
TVJ = 25°C
TVJ = TVJM
TVJ = 25°C
For power-loss calculations only
TVJ = TVJM
per diode; DC current
per module
per diode; DC current
per module
Creeping distance on surface
Creeping distance in air
Max. allowable acceleration
Characteristic Value
≤
5.0
mA
≤
30
mA
≤
1.25
V
typ. 150
ns
0.25
V
0.43
mΩ
0.28
K/W
0.14
0.38
K/W
0.19
10
mm
9.4
mm
50
m/s2
Features
• Package with screw terminals
• Isolation voltage 3000 V∼
• Planar glasspassivated chips
• Short recovery time
• Low forward voltage drop
• Short recovery behaviour
• UL registered, E 148688
Applications
• Inductive heating and melting
• Free wheeling diode in
converters and motor control
circuits
• Uninterruptible power supplies
(UPS)
• Ultrasonic cleaners and welders
Advantages
• High reliability circuit operation
• Low voltage peaks for reduced
protection circuits
• Low noise switching
• Low losses
Package, style and outline
Dimensions in mm (1mm = 0.0394“)
POWERSEM GmbH, Walpersdorfer Str. 53
91126 D- Schwabach
Phone: 09122 - 9764-0 Fax.: 09122 - 9764-20
 2003 POWERSEM reserves the right to change limits, test conditions and dimensions