PR560 Reed Switch
REACH & RoHS Compliant
Contact Information:
Standex-Meder Electronics
World Headquarters
4538 Camberwell Road
Cincinnati, OH 45209 USA
Standex Americas (OH)
+1.866.STANDEX
(+1.866.782.6339)
info@standexelectronics.com
Meder Americas (MA)
+1.800.870.5385
salesusa@standexmeder.com
Standex-Meder Asia (Shanghai)
+86.21.37820625
salesasia@standexmeder.com
Standex-Meder Europe (Germany)
+49.7731.8399.0
info@standexmeder.com
Professional grade high voltage medium power applications reed switch with rhodium
contacts
Designed to give superior life switching relatively heavy loads
Physical Characteristics
A Glass Length (Max.)
B Overall Length (Max.)
C Glass Diameter (Max.)
D Lead Diameter (Nom.)
14.2 mm
54.0 mm
2.3 mm
0.6 mm
Electrical Characteristics
Contact Arrangement
Form A (SPST), Center Gap
Contact Material
Power Rating 1
Rhodium
10VA maximum
Switching Current (Max.)
1.0 Amp. DC, 1.0 Amp. AC
Carry Current (Max.)
1.5 Amp. DC, 1.5 Amp. AC
Switching Voltage (Max.)
Breakdown Voltage (Min. @20AT) 2
Contact Resistance 3
Insulation Resistance (Min.)
250 VDC, 250 VAC
600 Volts DC
100 Milliohms
1012 ohms
Contact Capacitance (pf Max.)
0.2 pf
1. The specification for VA rating may sometimes be exceeded for less sensitive (higher AT) switches, and should be
decreased for very sensitive (lower AT) switches. Standex-Meder Electronics will run life tests specific to a customer’s
load upon request.
2. Breakdown voltage is measured in the presence of a radioactive ionising source. Switch leakage current is limited to
100 microamperes
3. Contact resistance measurements are made at 10ma from a 1-volt source, with 50% overdrive, using a 4-wire (Kelvin)
measuring system. Contact probes are located on 43 mm centres.
Minimum Switching Life with Standard Test Loads, using 20AT switch
Voltage
24 VDC
100 VDC
125 VAC
240 VDC
Current
Life
10 mA
5 x 106
100 mA
1 x 106
80 mA
1 x 106
40 mA
2 x 105
Note: End of life is defined as contact resistance exceeding one ohm and/or failure to operate.
240 VAC
40 mA
5 x 105