English
Language : 

SD-1000_1109 Datasheet, PDF (3/4 Pages) Mean Well Enterprises Co., Ltd. – 1000W Single Output DC-DC Converter
1000W Single Output DC-DC Converter
SD-1000 series
Function Description of CN51
Pin No. Function Description
1
+S
Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
2
-S
Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
3
O/P OK
Open collector signal, referenced to pin4(GND). Low when PSU turns on. The maximum sink current is 10mA and the maximum
external voltage is 13V.
4
GND These pins connect to the negative terminal (-V).
5
AUX Auxiliary voltage output, 10.8~13.2V referenced to pin6(AUXG).The maximum load current is 0.25A.
6 AUXG Auxiliary voltage output ground. The signal return is isolated from the output terminals(+V & -V).
7
RC1 Remote ON/OFF
8
RC2 Remote ON/OFF
9
RCG Remote ON/OFF ground
10
NC No connection
Function Manual
1.Remote ON/OFF
(1)Remote ON/OFF control becomes available by applying voltage in CN51
(2)Table 1.1 shows the specification of Remote ON/OFF function
(3)Fig.1.2 shows the example to connect Remote ON/OFF control function
Table 1.1 Specification of Remote ON/OFF
Connection Method Fig. 1.2(A)
SW Logic
Output on
Output off
SW Open
SW Close
Fig. 1.2(B)
SW Open
SW Close
Fig. 1.2(C)
SW Close
SW Open
Fig.1.2 Examples of connecting remote ON/OFF
(A)Using external voltage source
(B)Using internal 12V auxiliary output
12V typ.
AUX
2.2K
RC1
150
5V
RC2
620
SW
RCG
AUXG
12V typ.
AUX
2.2K
RC1
150
RC2
RCG
SW
AUXG
(C)Using internal 12V auxiliary output
12V typ.
AUX
2.2K
RC1
150
RC2
SW
RCG
AUXG
File Name:SD-1000-SPEC 2011-08-23