English
Language : 

DRA-60 Datasheet, PDF (3/5 Pages) Mean Well Enterprises Co., Ltd. – UNIVERSAL AC INPUT/FULL RANGE
60W Single Output Switching Power Supply
Block Diagram
DRA-60 series
I/P
EMI
FILTER
FG
RECTIFIERS
&
FILTER
POWER
SWITCHING
O.L.P.
CONTROL
RECTIFIERS
&
FILTER
O.C.P.
DETECTION
CIRCUIT
O.V.P.
+V
-V
DIM+
DIM-
Derating Curve
Static Characteristics
100
80
230VAC
Input only
60
40
20
-30 -20
0
15
30
40
50
60
70 (VERTICAL)
AMBIENT TEMPERATURE (℃)
100
90
80
70
60
50
40
90 100 125 135 145 155 165 175 180 200 230 264
INPUT VOLTAGE (V) 60Hz
OUTPUT CURRENT ADJUSTMENT OPERATION
※ Built-in 3 in 1 current adjustment function . Output constant current level can be adjusted by applying 1 ~ 10Vdc, 10V PWM
signal or resistance between DIM+ and DIM-.
※ Please DO NOT connect "DIM-" to "-V".
※ Reference resistance value for output current adjustment (Typical)
Resistance Single Power supply
value
Multiple Power supplies
(N=Power supply quantity for simultaneous
current adjustment control)
Percentage of rated current
10KΩ 20KΩ 30KΩ 40KΩ 50KΩ 60KΩ 70KΩ 80KΩ 90KΩ 100KΩ OPEN
10KΩ/N 20KΩ/N 30KΩ/N 40KΩ/N 50KΩ/N 60KΩ/N 70KΩ/N 80KΩ/N 90KΩ/N 100KΩ/N -----
10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 102%~108%
※ 1 ~ 10Vdc for output current adjustment (Typical)
Applied Source
1V 2V 3V 4V 5V 6V 7V 8V 9V 10V OPEN
Percentage of rated current
10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 102%~108%
※ 10V PWM signal for output current adjustment (Typical): Frequency range :100Hz ~ 3KHz
Duty value
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
OPEN
Percentage of rated current
10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 102%~108%
File Name:DRA-60-SPEC 2015-06-11