English
Language : 

UHP-350 Datasheet, PDF (2/6 Pages) Mean Well Enterprises Co., Ltd. – 350W Slim Type with PFC Switching Power Supply
350W Slim Type with PFC Switching Power Supply
UHP-350 series
SPECIFICATION
MODEL
UHP-350 -3.3 UHP-350 -4.2 UHP-350 -5 UHP-350 -12 UHP-350 -15 UHP-350 -24 UHP-350 -36 UHP-350 -48
DC VOLTAGE
RATED CURRENT
3.3V
4.2V
5V
12V
15V
24V
36V
48V
60A
60A
60A
29.2A
23.4A
14.6A
9.75A
7.3A
OUTPUT
RATED POWER(convection)
198W
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE
3.2~3.5V
VOLTAGE TOLERANCE Note.3 ±2.0%
LINE REGULATION
LOAD REGULATION
±0.5%
±1.0%
252W
150mVp-p
3.6~4.4V
±2.0%
±0.5%
±1.0%
300W
200mVp-p
4.5~5.5V
±2.0%
±0.5%
±1.0%
350.4W
200mVp-p
11.4~12.6V
±1.0%
±0.3%
±0.5%
351W
200mVp-p
14.3~15.8V
±1.0%
±0.3%
±0.5%
350.4W
240mVp-p
22.8~25.2V
±1.0%
±0.3%
±0.5%
351W
240mVp-p
34.2~37.8V
±1.0%
±0.3%
±0.5%
350.4W
240mVp-p
45.6~50.4V
±1.0%
±0.3%
±0.5%
SETUP, RISE TIME
HOLD UP TIME (Typ.)
2000ms, 80ms/230VAC 3000ms, 80ms/115VAC at full load
10ms/230VAC 10ms/115VAC
VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF≥0.94/230VAC PF≥0.98/115VAC at full load
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
88.5%
89%
90%
91%
92%
94%
94%
94%
4A/115VAC 2A/230VAC
INRUSH CURRENT (Typ.)
Cold start 30A/115VAC 60A/230VAC
LEAKAGE CURRENT
<0.75mA / 240VAC
OVERLOAD
110~140% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
DC OK SIGNAL(Optional)
3.8 ~ 4.6V
4.62 ~ 5.46V 5.75 ~ 6.75V 13.2 ~ 15.6V 16.5 ~ 19.5V 26.4 ~ 31.2V
Protection type :Shut down O/P voltage,re-power on to recover
Protection type :Shut down O/P voltage, recovers automatically after temperature goes down
Contact rating(max.):15Vdc/10mA resistive load
39.6 ~46.8V
52.8 ~ 62.4V
FUNCTION REDUNDANT(Optional)
For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be automatically
enabled. This can prevent the system crash, and provide the reliability of system
WORKING TEMP.
-30 ~ +70℃(Refer to “Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1,TUV EN60950-1,EN60335-1,CCC GB4943 approved
SAFETY &
EMC
(Note.6)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH
Compliance to EN55032,GB9254,Class B, EN55014,EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11;EN61000-6-2 (EN50082-2), heavy industry level ,criterial A
MTBF
285 K hrs min. MIL-HDBK-217F (25℃)
OTHERS DIMENSION
PACKING
220*62*31mm (L*W*H)
0.68 kg;16 pcs/11.88 kg/0.63CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance :includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5.The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft)
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.
meanwell.com)
File Name:UHP-350-SPEC 2017-08-23