200W Single Output with PFC Function
UHP-200A series
SPECIFICATION
MODEL
UHP-200A-4.2
UHP-200A-4.5
UHP-200A-5
OUTPUT
DC VOLTAGE
4.2V
4.5V
RATED CURRENT
40A
40A
CURRENT RANGE
0 ~ 40A
0 ~ 40A
RATED POWER(convection) 168W
180W
RIPPLE & NOISE (max.) Note.2 200mVp-p
200mVp-p
VOLTAGE ADJ. RANGE
4.0~4.4V
4.3~4.7V
VOLTAGE TOLERANCE Note.3 ±4.0%
±4.0%
LINE REGULATION
±0.5%
±0.5%
LOAD REGULATION
±2.5%
±2.5%
SETUP, RISE TIME
2000ms, 200ms/230VAC at full load, 3000ms, 200ms/115VAC at 80% load
5V
40A
0 ~ 40A
200W
200mVp-p
4.7~5.3V
±4.0%
±0.5%
±2.5%
HOLD UP TIME (Typ.)
DC OK FUNCTION
10ms/230VAC 10ms/115VAC
PSU Turns on:DC ok; PSU turns off:DC fail
INPUT
VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF≥0.97/115VAC PF≥0.95/230VAC at full load
EFFICIENCY (Typ.)
88%
88%
AC CURRENT (Typ.)
3.0A/115VAC 2.0A/230VAC
INRUSH CURRENT (Typ.) Cold start 85A/230VAC
88.5%
LEAKAGE CURRENT
OVERLOAD
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
<1.0mA / 240VAC
110~140% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
4.6 ~ 6V
5 ~ 6.4V
5.6 ~ 7.1V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER TEMPERATURE
Protection type : Shut down O/P voltage, recovers automatically after fault condition is removed
WORKING TEMP.
-30 ~ +50℃(Refer to “OUTPUT LOAD vs TEMPERATURE")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1,TUV EN60950-1,CCC GB4943 approved
SAFETY &
EMC
(Note 5)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION Note.8
EMC IMMUNITY
I/P-O/P:3.0KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25℃/ 70%RH
Compliance to EN55032 (CISPR32),GB9254,Class A, EN61000-3-2,-3,GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11;EN55024, light industry level (surge 4KV)
MTBF
204K hrs min. MIL-HDBK-217F (25℃)
OTHERS DIMENSION
167*55*26mm (L*W*H)
PACKING
0.42kg; 20pcs/ 11.4kg/0.76CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. Transient response meansure shall be made with 10% load at least.
7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
8. Warnning: This equipment is compliant with Class A of CISPR 32. In a residential environment may cause radio interference.
File Name:UHP-200A-SPEC 2017-07-21