UHP-200 Datasheet, PDF (2/6 Pages) Mean Well Enterprises Co., Ltd. – 200W Slim Type with PFC Switching Power Supply
200W Slim Type with PFC Switching Power Supply
UHP-200 series
SPECIFICATION
MODEL
UHP-200 -3.3 UHP-200 -4.2 UHP-200 -5 UHP-200 -12 UHP-200 -15 UHP-200 -24 UHP-200 -36 UHP-200 -48
DC VOLTAGE
3.3V
4.2V
5V
12V
15V
24V
36V
48V
RATED CURRENT
40A
40A
40A
16.7A
13.4A
8.4A
5.6A
4.2A
RATED POWER(convection)
132W
168W
200W
200.4W
201W
201.6W
201.6W
201.6W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
200mVp-p 240mVp-p
240mVp-p
240mVp-p 240mVp-p 300mVp-p
VOLTAGE ADJ. RANGE
3.2~3.5V
OUTPUT
VOLTAGE TOLERANCE Note.3 ±2.0%
3.6~4.4V
±2.0%
4.5~5.5V
±2.0%
11.4~12.6V
±1.0%
14.3~15.8V
±1.0%
22.8~25.2V
±1.0%
34.2~37.8V
±1.0%
45.6~50.4V
±1.0%
LINE REGULATION
±0.5%
±0.5%
±0.5%
±0.3%
±0.3%
±0.3%
±0.3%
±0.3%
LOAD REGULATION
±1.0%
±1.0%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
SETUP, RISE TIME
2000ms, 80ms/230VAC 3000ms, 80ms/115VAC at full load
HOLD UP TIME (Typ.)
10ms/230VAC 10ms/115VAC
VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF≥0.94/230VAC PF≥0.98/115VAC at full load
INPUT
EFFICIENCY (Typ.)
89%
90%
91%
93%
94%
94%
94%
94%
AC CURRENT (Typ.)
2.2A/115VAC 1.1A/230VAC
INRUSH CURRENT (Typ.)
Cold start 40A/115VAC 80A/230VAC
LEAKAGE CURRENT
<0.75mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
110~140% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8~ 4.6V
4.62 ~ 5.46V 5.75 ~ 6.75V 13.2 ~ 15.6V 16.5 ~ 19.5V 26.4 ~ 31.2V
Protection type :Shut down O/P voltage,re-power on to recover
39.6 ~46.8V
52.8 ~ 62.4V
OVER TEMPERATURE
Protection type :Shut down O/P voltage, recovers automatically after temperature goes down
FUNCTION
DC OK SIGNAL(Optional)
REDUNDANT(Optional)
Contact rating(max.):15Vdc/10mA resistive load
For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be automatically
enabled. This can prevent the system crash, and provide the reliability of system
WORKING TEMP.
-30 ~ +70℃(Refer to “Derating Curve")
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
20 ~ 90% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH non-condensing
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1,TUV EN60950-1,EN60335-1, CCC GB4943 approved
SAFETY &
EMC
(Note.6)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH
Compliance to EN55032,GB9254,Class B, EN55014,EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11;EN61000-6-2 (EN50082-2), heavy industry level ,criterial A
OTHERS
MTBF
DIMENSION
257K hrs min. MIL-HDBK-217F (25℃)
194*55*26mm (L*W*H)
NOTE
PACKING
0.468kg;24pcs/12.2kg/0.49CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance :includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft)
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets