English
Language : 

SGA12U Datasheet, PDF (2/3 Pages) Mean Well Enterprises Co., Ltd. – 12W AC-DC High Reliability Slim Wall-mounted Adaptor
S G A 1 2 U 12W AC-DC High Reliability Slim Wall-mounted Adaptor
series
SPECIFICATION
ORDER NO.
SGA12U05-□ SGA12U07-P1J SGA12U09-P1J SGA12U12-P1J SGA12U15-P1J SGA12U18-P1J SGA12U24-P1J SGA12U48-P1J
□=P1J, USB
SAFETY MODEL NO.
SGA12U05 SGA12U07 SGA12U09 SGA12U12 SGA12U15 SGA12U18 SGA12U24 SGA12U48
DC VOLTAGE
Note.2 5V
7.5V
9V
12V
15V
18V
24V
48V
RATED CURRENT
2.4A
1.6A
1.33A
1A
0.8A
0.666A
0.5A
0.25A
CURRENT RANGE
0 ~ 2.4A
0 ~ 1.6A
0 ~ 1.33A
0 ~ 1A
0 ~ 0.8A
0 ~ 0.666A 0 ~ 0.5A
0 ~ 0.25A
RATED POWER (max.)
12W
12W
12W
12W
12W
12W
12W
12W
OUTPUT RIPPLE & NOISE (max.) Note.3 50mVp-p
50mVp-p
80mVp-p
80mVp-p
80mVp-p
80mVp-p
100mVp-p 100mVp-p
VOLTAGE TOLERANCE Note.4 ±5.0%
±5.0%
±5.0%
±3.0%
±3.0%
±3.0%
±2.0%
±2.0%
LINE REGULATION Note.5 ±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
LOAD REGULATION Note.6 ±5.0%
±5.0%
±5.0%
±3.0%
±3.0%
±3.0%
±2.0%
±2.0%
SETUP, RISE, HOLD UP TIME 1300ms, 50ms, 12ms/230VAC 1300ms, 50ms, 12ms/115VAC at full load
VOLTAGE RANGE Note.7 90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
AC CURRENT
80%
83%
83%
83%
84.5%
85%
85%
86%
0.5A / 115VAC 0.25A / 230VAC
INRUSH CURRENT (max.) 30A / 115VAC 60A / 230VAC
LEAKAGE CURRENT(max.) 0.25mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
110 ~ 200% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110 ~ 140% rated output voltage
Protection type : Clamp by zener diode, output short
-20 ~ +60℃ (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-20 ~ +85℃, 10 ~ 95% RH
150 ~ 250% rated output power
TEMP. COEFFICIENT
±0.03% / ℃ (0 ~ 40℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY &
EMC
(Note. 8)
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
TUV EN60950-1 approved
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022 class B, EN61000-3-2,3
EMC IMMUNITY
LIFE
Compliance to EN61000-4,-2,3,4,5,6,8,11, light industry level, criteria A
3 years : 100% load 40℃, 8hours / day
MTBF
OTHERS DIMENSION
265Khrs min. MIL-HDBK-217F(25℃)
62.2*27.4*39.5mm (L*W*H)
PACKING
PLUG
CONNECTOR
CABLE
109g ; 110pcs / 13kg / CARTON for cable connection ; 56.2g ; 90pcs / 7.5kg / CARTON for USB connection
See page 3 ; Other type available by customer requested
See page 3 ; Other type available by customer requested
NOTE
1.All parameters are specified at 115VAC input, rated load, 25℃ 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load
7.Derating may be needed under low input voltages. Please check the static characteristics for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:SGA12U-SPEC 2015-12-09