ODLC-45 Datasheet, PDF (2/6 Pages) Mean Well Enterprises Co., Ltd. – CONSTANT CURRENT MODE OUTPUT
45W Constant Current Mode LED Driver
ODLC-45 series
SPECIFICATION
MODEL
ODLC-45 -350
ODLC-45 -500
ODLC-45 -700
ODLC-45 -1050
ODLC-45 -1400
RATED CURRENT
RATED POWER
350mA
33.25W
500mA
45W
700mA
44.8W
CONSTANT CURRENT REGION Note.2 57 ~ 95V
54 ~ 90V
38 ~ 64V
OUTPUT OPEN CIRCUIT VOLTAGE(max.) 118V
115V
84V
CURRENT RIPPLE
5% max. @rated current
CURRENT TOLERANCE ±7.0%
SETUP TIME Note.4
500ms / 230VAC 1200ms/115VAC
AUXILIARY DC OUTPUT Note.5 Nominal 12V(deviation 11.4~12.6)@50mA for A-Type only
VOLTAGE RANGE Note.3 90 ~ 295VAC
127 ~ 417VDC
(Please refer to "STATIC CHARACTERISTIC" section)
FREQUENCY RANGE 47 ~ 63Hz
1050mA
45.15W
26 ~ 43V
63V
1400mA
44.8W
19 ~ 32V
50V
POWER FACTOR (Typ.)
PF>0.95/115VAC, PF>0.92/230VAC, PF>0.9/277VAC@full load
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
THD< 20%(@load≧60%/230VAC; @load≧75%/277VAC)
INPUT TOTAL HARMONIC DISTORTION (Please refer to “TOTAL HARMONIC DISTORTION” section)
EFFICIENCY (Typ.)
86%
85%
85%
84%
83%
AC CURRENT
0.6A/115VAC 0.4A/230VAC 0.3A/277VAC
INRUSH CURRENT (Typ.) COLD START 30A(twidth=100μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
NO LOAD POWER CONSUMPTION <0.5W for Blank-Type
PROTECTION SHORT CIRCUIT
WORKING TEMP.
Hiccup mode, recovers automatically after fault condition is removed
Tcase=-20 ~ +85℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.
Tcase=+85℃
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 40℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL8750(type”HL”),CSA C22.2 NO.250.13-12;ENEC EN61347-1 & EN61347-2-13 independent, EN62384,GB19510.1,GB19510.14;
IP67 approved
WITHSTAND VOLTAGE I/P-O/P:3.75KVAC
SAFETY & ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC
EMC EMISSION
Compliance to EN55015, EN61000-3-2 Class C (@load≧60%) ; EN61000-3-3,GB17743,GB17625.1
EMC IMMUNITY
MTBF
OTHERS DIMENSION
PACKING
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge immunity:Line-Line:1KV)
408.8Khrs min. MIL-HDBK-217F (25℃)
111*77*28.5mm(L*W*H)
0.42Kg; 24pcs/ 11Kg/ 0.72CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
2. Please refer to "DRIVING METHODS OF LED MODULE".
3. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
4. Length of set up time is measured at cold first start. Turning ON/OFF the driver may lead to increase of the set up time.
5. There is no design of short circuit protection for the Auxiliary DC output; this function can not be used when dimming input terminals(DIM+,DIM-)
are short circuit or when it is no load or short circuit at output(Vo+,Vo-).
6. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be
affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:ODLC-45-SPEC 2016-10-26