English
Language : 

LRS-100 Datasheet, PDF (2/4 Pages) Mean Well Enterprises Co., Ltd. – 100W Single Output Switching Power Supply
100W Single Output Switching Power Supply
LRS-100 series
SPECIFICATION
MODEL
LRS-100-3.3 LRS-100-5 LRS-100-12 LRS-100-15 LRS-100-24 LRS-100-36 LRS-100-48
DC VOLTAGE
3.3V
5V
12V
15V
RATED CURRENT
20A
18A
8.5A
7A
CURRENT RANGE
0 ~ 20A
0 ~ 18A
0 ~ 8.5A
0 ~ 7A
RATED POWER
66W
90W
102W
105W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 120mVp-p 120mVp-p
OUTPUT VOLTAGE ADJ. RANGE 2.97 ~ 3.6V 4.5 ~ 5.5V 10.2 ~ 13.8V 13.5 ~ 18V
VOLTAGE TOLERANCE Note.3 ±3.0%
±2.0%
±1.0%
±1.0%
LINE REGULATION Note.4 ±0.5%
±0.5%
±0.5%
±0.5%
LOAD REGULATION Note.5 ±2.0%
±1.0%
±0.5%
±0.5%
SETUP, RISE TIME
500ms, 30ms/230VAC 500ms,30ms/115VAC at full load
24V
4.5A
0 ~ 4.5A
108W
150mVp-p
21.6 ~ 28.8V
±1.0%
±0.5%
±0.5%
36V
2.8A
0 ~ 2.8A
100.8W
200mVp-p
32.4 ~ 39.6V
±1.0%
±0.5%
±0.5%
48V
2.3A
0 ~ 2.3A
110.4W
200mVp-p
43.2 ~ 52.8V
±1.0%
±0.5%
±0.5%
HOLD UP TIME (Typ.) 55ms/230VAC 10ms/115VAC at full load
VOLTAGE RANGE
85 ~ 264VAC 120 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
INPUT
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.)
84.5%
86%
88%
AC CURRENT (Typ.)
1.9A/115VAC 1.2A/230VAC
INRUSH CURRENT (Typ.) COLD START 50A/230VAC
88.5%
90%
90.5%
91%
LEAKAGE CURRENT
<0.75mA / 240VAC
OVER LOAD
PROTECTION
OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.45V 5.75 ~ 6.75V 13.8 ~ 16.2V 18.75 ~ 21.75V 28.8 ~ 33.6V 41.4 ~ 48.6V
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-30 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
55.2 ~ 64.8V
SAFETY STANDARDS UL60950-1, TUV EN60950-1, EN60335-1, EN61558-1/-2-16,CCC GB4943 approved
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note 8) EMC EMISSION
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022 (CISPR22), GB9254 Class B, EN55014 EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
MTBF
720.6K hrs min. MIL-HDBK-217F (25℃)
OTHERS DIMENSION
129*97*30mm (L*W*H)
PACKING
0.34Kg ; 40pcs/14.6Kg/0.92CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up
time.
7. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft).
8. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed
that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power
supplies.” (as available on http://www.meanwell.com)
File Name:LRS-100-SPEC 2015-12-31