English
Language : 

LPV-150 Datasheet, PDF (2/3 Pages) Mean Well Enterprises Co., Ltd. – 150W Single Output Switching Power Supply
150W Single Output Switching Power Supply
LPV-150 series
SPECIFICATION
MODEL
LPV -150-12
LPV-150-15
LPV -150-24
LPV-150-36
LPV-150-48
OUTPUT
DC VOLTAGE
12V
RATED CURRENT
10A
CURRENT RANGE
0 ~ 10A
RATED POWER
120W
RIPPLE & NOISE (max.) Note.2 200mVp-p
VOLTAGE TOLERANCE Note.3 ±5.0%
LINE REGULATION
±1.0%
LOAD REGULATION
±2.0%
15V
8A
0 ~ 8A
120W
200mVp-p
24V
6.3A
0 ~ 6.3A
151.2W
200mVp-p
36V
4.2A
0 ~ 4.2A
151.2W
200mVp-p
48V
3.2A
0 ~ 3.2A
153.6W
200mVp-p
SETUP, RISE TIME Note.6 LPV-150: 500ms, 50ms / 230VAC 500ms, 50ms / 277VAC;
LPVL-150: 1500ms, 50ms / 115VAC
HOLD UP TIME (Typ.)
LPV-150: 18ms/230VAC 20ms/277VAC at full load;
LPVL-150: 10ms/115VAC at full load
VOLTAGE RANGE Note.4 LPV-150: 180 ~ 305VAC 254 ~ 431VDC;
FREQUENCY RANGE
47 ~ 63Hz
LPVL-150: 90~132VAC 254 ~ 370VDC
EFFICIENCY (Typ.)
87%
88%
89%
89%
90%
INPUT
AC CURRENT
LPV-150: 1.7A/230VAC 1.5A/277VAC;
LPVL-150: 3.0A/115VAC
INRUSH CURRENT Blank type COLD START 60A(twidth=900μs measured at 50% Ipeak) at 230VAC
(Typ.)
L type COLD START 75A(twidth=900μs measured at 50% Ipeak) at 115VAC
MAX. No. of PSUs Blank type 2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC
on 16A CIRCUIT
BREAKER
L type 1 units (circuit breaker of type B) / 2 units (circuit breaker of type C) at 115VAC
LEAKAGE CURRENT
LPV-150: 0.25mA / 240VAC
LPVL-150:0.25mA / 120VAC
OVERLOAD
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
OVER VOLTAGE
13.5 ~ 18V
17 ~ 25V
27 ~ 35V
Protection type : Shut down o/p voltage, re-power on to recover
40 ~ 49V
52 ~ 63V
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
-25 ~ +65℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 40℃ for LPV-150-12,15 and LPVL-150-12,24;0~50℃ for LPV-150-24,36,48)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY
STANDARDS
Blank type UL8750,CSA C22.2 No 250.13-12,UL879,CSA C22.2 No.207-M89,IP67 approved. Design refer to EN60950-1
L type UL8750(type”HL”),CSA C22.2 No 250.13-12,UL879,CSA C22.2 No.207-M89,IP67 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC
SAFETY & ISOLATION RESISTANCE
I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC
Blank type Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A(≤80% load), EN61000-3-3
EMC EMISSION
L type Compliance to FCC part 15
Blank type Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024, light industry level, criteria A
EMC IMMUNITY
L type Design refer to IEC61000-4-2,3,4,5,6,8,11; light industry level, criteria A
MTBF
OTHERS DIMENSION
703Khrs min. MIL-HDBK-217F (25℃)
191*63*37.5mm (L*W*H)
NOTE
PACKING
LPV-150: 0.74Kg;20pcs/15.8Kg/0.95CUFT; LPVL-150: 0.85Kg;20pcs/17Kg/0.95CUFT
1. All parameters NOT specially mentioned are measured at 230VAC(115VAC for LPVL) input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
8. Suitable for indoor use or outdoor use without direct sunlight exposure.
File Name:LPV-150-SPEC 2015-09-01