HLG-600H Datasheet, PDF (2/8 Pages) Mean Well Enterprises Co., Ltd. – CONSTANT VOLTAGE+CONSTANT CURRENT MODE OUTPUT | |||
|
◁ |
H L G - 6 0 0 H 600W Constant Voltage + Constant Current LED Driver
series
SPECIFICATION
MODEL
HLG-600H-12 HLG-600H-15 HLG-600H-20 HLG-600H-24 HLG-600H-30 HLG-600H-36 HLG-600H-42 HLG-600H-48 HLG-600H-54
OUTPUT
DC VOLTAGE
12V
15V
20V
24V
30V
36V
42V
48V
54V
CONSTANT CURRENT REGION Note.4 6 ~12V
7.5 ~ 15V 10 ~ 20V 12 ~ 24V 15 ~ 30V 18 ~ 36V 21 ~ 42V 24 ~ 48V 27 ~ 54V
RATED CURRENT
40A
36A
28A
25A
20A
16.7A
14.3A
12.5A
11.2A
RATED POWER
480W
540W
560W
600W
600W
601.2W
600.6W
600W
604.8W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 250mVp-p 250mVp-p 250mVp-p 350mVp-p
VOLTAGE ADJ. RANGE
Adjustable for A-Type only (via built-in potentiometer)
10.2 ~ 12.6V 12.7 ~ 15.8V 17 ~ 21V 20.4 ~ 25.2V 25.5 ~ 31.5V 30.6 ~ 37.8V 35.7 ~ 44.1V 40.8 ~ 50.4V 45.9 ~ 56.7V
CURRENT ADJ. RANGE
Adjustable for A-Type only (via built-in potentiometer)
20 ~ 40A 18 ~ 36A 14 ~ 28A 12.5 ~ 25A 10 ~ 20A
8.3 ~ 16.7A 7.1 ~ 14.3A 6.2 ~ 12.5A 5.6 ~ 11.2A
VOLTAGE TOLERANCE Note.3 ±3.0%
±2.0%
±1.5%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
LINE REGULATION
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
LOAD REGULATION
±2.0%
±1.5%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
SETUP, RISE TIME Note.6 500ms, 80ms/ 115VAC, 230VAC
HOLD UP TIME (Typ.)
15ms / 115VAC, 230VAC
VOLTAGE RANGE
90 ~ 305VAC 127 ~ 431VDC
Note.5 (Please refer to "STATIC CHARACTERISTIC" section)
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PFâ§0.98/115VAC, PFâ§0.95/230VAC, PFâ§0.93/277VAC @ full load
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
TOTAL HARMONIC DISTORTION THD< 20% (@ loadâ§50% /115VAC, 230VAC; @ loadâ§75%/277VAC)
(Please refer to âTOTAL HARMONIC DISTORTION (THD)â section)
INPUT
EFFICIENCY
(Typ.)
230VAC 92%
277VAC 92.5%
93.5%
93.5%
94.5%
94.5%
95%
95%
95%
95%
95.5%
96%
95.5%
96%
96%
96%
96%
96%
AC CURRENT (Typ.)
7A / 115VAC 3.3A / 230VAC 2.9A / 277VAC
INRUSH CURRENT(Typ.)
COLD START 70A(twidth=1000μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
1 unit (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
STANDBY POWER CONSUMPTION <0.5W at remote off
OVER CURRENT
95 ~ 108%
Note.4
Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
Constant current limiting, recovers automatically after fault condition is removed
13 ~ 16V 16.5 ~ 20.5V 22 ~ 26V 26 ~ 30V 32.5 ~ 36.5V 39.5 ~ 43.5V 46 ~ 50V
Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, re-power on to recover
REMOTE ON/OFF CONTROL Power on : "High" >2 ~ 5V or Open circuit Power off : "Low" <0 ~ 0.5V or Short circuit
FUNCTION
5V STANDBY
5VSB : 5V@0.5A ; tolerance ±5%, ripple : 100mVp-p(max.)
WORKING TEMP.
Tcase= -40 ~ +90â (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
MAX. CASE TEMP.
Tcase= +90â
WORKING HUMIDITY
20 ~ 95% RH non-condensing
ENVIRONMENT
STORAGE TEMP., HUMIDITY
-40 ~ +85â, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/â (0 ~ 55â)
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
52.5 ~ 56.5V 59 ~ 63V
SAFETY &
EMC
(Note 9)
UL60950-1, UL8750(typeâHLâ), CSA C22.2 No. 250.13-12, ENEC EN61347-1, EN61347-2-13 independent, EN62384, IP65 or IP67,
SAFETY STANDARDS Note.8
J61347-1, J61347-2-13 approved
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25â/ 70% RH
EMC EMISSION
Note.8 Compliance to EN55015, EN55022(CISPR22) Class B, EN61000-3-2 Class C (@ loadâ§50%) ; EN61000-3-3
OTHERS
NOTE
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV)
MTBF
76.9K hrs min. MIL-HDBK-217F (25â)
DIMENSION
280*144*48.5mm (L*W*H)
PACKING
3.9Kg; 4pcs/16.6Kg/0.9CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25â of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. De-rating may be needed under low input voltages. Please refer to ÂSTATIC CHARACTERISTICÂ sections for details.
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
7. The driver is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a
360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to ÂEMI testing of component power supplies. (as available on http://www.meanwell.com)
8. The model certified for CCC(GB19510.14, GB19510.1, GB17743 and GB17625.1) is an optional model . Please contact MEAN WELL for details.
9. This series meets the typical life expectancy of >62,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75â or less.
10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
File Name:HLG-600H-SPEC 2016-10-27
|
▷ |