English
Language : 

HLG-600H Datasheet, PDF (2/8 Pages) Mean Well Enterprises Co., Ltd. – CONSTANT VOLTAGE+CONSTANT CURRENT MODE OUTPUT
H L G - 6 0 0 H 600W Constant Voltage + Constant Current LED Driver
series
SPECIFICATION
MODEL
HLG-600H-12 HLG-600H-15 HLG-600H-20 HLG-600H-24 HLG-600H-30 HLG-600H-36 HLG-600H-42 HLG-600H-48 HLG-600H-54
OUTPUT
DC VOLTAGE
12V
15V
20V
24V
30V
36V
42V
48V
54V
CONSTANT CURRENT REGION Note.4 6 ~12V
7.5 ~ 15V 10 ~ 20V 12 ~ 24V 15 ~ 30V 18 ~ 36V 21 ~ 42V 24 ~ 48V 27 ~ 54V
RATED CURRENT
40A
36A
28A
25A
20A
16.7A
14.3A
12.5A
11.2A
RATED POWER
480W
540W
560W
600W
600W
601.2W
600.6W
600W
604.8W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 250mVp-p 250mVp-p 250mVp-p 350mVp-p
VOLTAGE ADJ. RANGE
Adjustable for A-Type only (via built-in potentiometer)
10.2 ~ 12.6V 12.7 ~ 15.8V 17 ~ 21V 20.4 ~ 25.2V 25.5 ~ 31.5V 30.6 ~ 37.8V 35.7 ~ 44.1V 40.8 ~ 50.4V 45.9 ~ 56.7V
CURRENT ADJ. RANGE
Adjustable for A-Type only (via built-in potentiometer)
20 ~ 40A 18 ~ 36A 14 ~ 28A 12.5 ~ 25A 10 ~ 20A
8.3 ~ 16.7A 7.1 ~ 14.3A 6.2 ~ 12.5A 5.6 ~ 11.2A
VOLTAGE TOLERANCE Note.3 ±3.0%
±2.0%
±1.5%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
LINE REGULATION
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
LOAD REGULATION
±2.0%
±1.5%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
SETUP, RISE TIME Note.6 500ms, 80ms/ 115VAC, 230VAC
HOLD UP TIME (Typ.)
15ms / 115VAC, 230VAC
VOLTAGE RANGE
90 ~ 305VAC 127 ~ 431VDC
Note.5 (Please refer to "STATIC CHARACTERISTIC" section)
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF≧0.98/115VAC, PF≧0.95/230VAC, PF≧0.93/277VAC @ full load
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
TOTAL HARMONIC DISTORTION THD< 20% (@ load≧50% /115VAC, 230VAC; @ load≧75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)
INPUT
EFFICIENCY
(Typ.)
230VAC 92%
277VAC 92.5%
93.5%
93.5%
94.5%
94.5%
95%
95%
95%
95%
95.5%
96%
95.5%
96%
96%
96%
96%
96%
AC CURRENT (Typ.)
7A / 115VAC 3.3A / 230VAC 2.9A / 277VAC
INRUSH CURRENT(Typ.)
COLD START 70A(twidth=1000μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
1 unit (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
STANDBY POWER CONSUMPTION <0.5W at remote off
OVER CURRENT
95 ~ 108%
Note.4
Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
Constant current limiting, recovers automatically after fault condition is removed
13 ~ 16V 16.5 ~ 20.5V 22 ~ 26V 26 ~ 30V 32.5 ~ 36.5V 39.5 ~ 43.5V 46 ~ 50V
Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, re-power on to recover
REMOTE ON/OFF CONTROL Power on : "High" >2 ~ 5V or Open circuit Power off : "Low" <0 ~ 0.5V or Short circuit
FUNCTION
5V STANDBY
5VSB : 5V@0.5A ; tolerance ±5%, ripple : 100mVp-p(max.)
WORKING TEMP.
Tcase= -40 ~ +90℃ (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
MAX. CASE TEMP.
Tcase= +90℃
WORKING HUMIDITY
20 ~ 95% RH non-condensing
ENVIRONMENT
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 55℃)
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
52.5 ~ 56.5V 59 ~ 63V
SAFETY &
EMC
(Note 9)
UL60950-1, UL8750(type”HL”), CSA C22.2 No. 250.13-12, ENEC EN61347-1, EN61347-2-13 independent, EN62384, IP65 or IP67,
SAFETY STANDARDS Note.8
J61347-1, J61347-2-13 approved
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Note.8 Compliance to EN55015, EN55022(CISPR22) Class B, EN61000-3-2 Class C (@ load≧50%) ; EN61000-3-3
OTHERS
NOTE
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV)
MTBF
76.9K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
280*144*48.5mm (L*W*H)
PACKING
3.9Kg; 4pcs/16.6Kg/0.9CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
7. The driver is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a
360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
8. The model certified for CCC(GB19510.14, GB19510.1, GB17743 and GB17625.1) is an optional model . Please contact MEAN WELL for details.
9. This series meets the typical life expectancy of >62,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less.
10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
File Name:HLG-600H-SPEC 2016-10-27