English
Language : 

HDR-30 Datasheet, PDF (2/4 Pages) Mean Well Enterprises Co., Ltd. – SUULTRA SLIM DESIGN WITH 35MM(2SU) WIDTH
30W Ultra Slim Step Shape DIN Rail
HDR-30 series
SPECIFICATION
MODEL
HDR-30-5
HDR-30-12
HDR-30-15
HDR-30-24
HDR-30-48
DC VOLTAGE
5V
12V
15V
24V
48V
RATED CURRENT
3A
2A
2A
1.5A
0.75A
CURRENT RANGE
0 ~ 3A
0 ~ 2A
0 ~ 2A
0 ~ 1.5A
0 ~ 0.75A
RATED POWER
15W
24W
30W
36W
36W
RIPPLE & NOISE (max.) Note.2 80mVp-p
120mVp-p
120mVp-p
150mVp-p
240mVp-p
OUTPUT VOLTAGE ADJ. RANGE 4.5 ~ 5.5V
10.8 ~ 13.8V
13.5 ~ 18V
21.6 ~ 29V
43.2 ~ 55.2V
VOLTAGE TOLERANCE Note.3 ±2.0%
±1.0%
±1.0%
±1.0%
±1.0%
LINE REGULATION
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
LOAD REGULATION
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
SETUP, RISE TIME
500ms, 50ms/230VAC 500ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
30ms/230VAC 12ms/115VAC at full load
VOLTAGE RANGE
85 ~ 264VAC (277VAC available ) 120 ~ 370VDC (390VDC available )
FREQUENCY RANGE
47 ~ 63Hz
INPUT EFFICIENCY (Typ.)
82%
88%
89%
89%
90%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0.88A/115VAC 0.48A/230VAC
COLD START 25A/115VAC 45A/230VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
Note.4
105 ~ 160% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
5.75 ~ 7.5V
15 ~ 18V
18.8 ~ 22.5V
30 ~ 36V
Protection type : Shut down o/p voltage, re-power on to recover
57.6~ 67.2V
WORKING TEMP.
-30 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
VIBRATION
±0.03%/℃ (0 ~ 50℃) RH non-condensing
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
OPERATING ALTITUDE
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
(Note 5)
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS DIMENSION
2000 meters
UL60950-1, UL508, TUV EN61558-2-16, IEC60950-1 approved; Design refer to EN50178,TUV EN60950-1
I/P-O/P:3KVAC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Parameter
Standard
Test Level / Note
Conducted
Radiated
EN55032(CISPR32)
EN55032(CISPR32)
Class B
Class B
Harmonic Current
EN61000-3-2
Class A
Voltage Flicker
EN61000-3-3
-------
EN55024, EN55035, EN61000-6-2, EN61204-3
Parameter
Standard
Test Level /Note
ESD
Radiated Susceptibility
EFT/Burest
EN61000-4-2
EN61000-4-3
EN61000-4-4
Level 3, 8KV air; Level 2, 4KV contact, criteria A
Level 3, criteria A
Level 3, criteria A
Surge
EN61000-4-5
Level 4,2KV/L-N, criteria A
Conducted
Magnetic Field
Voltage Dips and interruptions
EN61000-4-6
EN61000-4-8
EN61000-4-11
Level 3, criteria A
Level 4, criteria A
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
968.1K hrs min. MIL-HDBK-217F (25℃)
35*90*54.5mm (W*H*D)
PACKING
0.12Kg;96pcs/12.5Kg/1.04CUFT
NOTE
℃







File Name:HDR-30-SPEC 2016-11-04