15W Ultra Slim Step Shape DIN Rail
HDR-15 series
SPECIFICATION
MODEL
HDR-15-5
HDR-15-12
HDR-15-15
HDR-15-24
HDR-15-48
OUTPUT
INPUT
DC VOLTAGE
5V
12V
15V
RATED CURRENT
2.4A
1.25A
1A
CURRENT RANGE
0 ~ 2.4A
0 ~ 1.25A
0 ~ 1A
RATED POWER
12W
15W
15W
RIPPLE & NOISE (max.) Note.2 80mVp-p
120mVp-p
120mVp-p
VOLTAGE ADJ. RANGE
4.5 ~ 5.5V
10.8 ~ 13.8V
13.5 ~ 18V
VOLTAGE TOLERANCE Note.3 ±2.0%
±1.0%
±1.0%
LINE REGULATION
±1.0%
±1.0%
±1.0%
LOAD REGULATION
±1.0%
±1.0%
±1.0%
SETUP, RISE TIME
2000ms, 80ms/230VAC 2000ms, 80ms/115VAC at full load
HOLD UP TIME (Typ.)
30ms/230VAC 12ms/115VAC at full load
VOLTAGE RANGE
85 ~ 264VAC (277VAC available ) 120 ~ 370VDC (390VDC available )
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
80%
85%
85.5%
AC CURRENT (Typ.)
0.5A/115VAC 0.25A/230VAC
INRUSH CURRENT (Typ.) COLD START 25A/115VAC 45A/230VAC
24V
0.63A
0 ~ 0.63A
15.2W
150mVp-p
21.6 ~ 29V
±1.0%
±1.0%
±1.0%
86%
48V
0.32A
0 ~ 0.32A
15.4W
240mVp-p
43.2 ~ 55.2V
±1.0%
±1.0%
±1.0%
87%
OVERLOAD
PROTECTION
OVER VOLTAGE
110 ~ 145% rated output power
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
5.75 ~ 6.75V
14.2 ~ 16.2V
18.8 ~ 22.5V
30 ~ 36V
Protection type : Shut off o/p voltage, clamping by zener diode
56.5~ 64.8V
WORKING TEMP.
WORKING HUMIDITY
-30 ~ +70℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃) RH non-condensing
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
OPERATING ALTITUDE 2000 meters
SAFETY STANDARDS
UL60950-1, UL508, TUV EN61558-2-16, IEC60950-1 approved; Design refer to EN50178,TUV EN60950-1
SAFETY & WITHSTAND VOLTAGE
I/P-O/P:3KVAC
EMC
(Note 5)
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Parameter
Standard
Test Level / Note
Conducted
EN55032(CISPR32)
Class B
EMC EMISSION
Radiated
EN55032(CISPR32)
Class B
Harmonic Current
EN61000-3-2
Class A
Voltage Flicker
EN61000-3-3
-------
EN55024, EN55035, EN61000-6-2, EN61204-3
Parameter
Standard
Test Level /Note
ESD
EN61000-4-2
Level 3, 8KV air; Level 2, 4KV contact, criteria A
EMC IMMUNITY
Radiated Susceptibility
EFT/Burest
Surge
EN61000-4-3
EN61000-4-4
EN61000-4-5
Level 3, criteria A
Level 3, criteria A
Level 4,2KV/L-N, criteria A
Conducted
EN61000-4-6
Level 3, criteria A
Magnetic Field
Voltage Dips and interruptions
EN61000-4-8
EN61000-4-11
Level 4, criteria A
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
MTBF
1166K hrs min. MIL-HDBK-217F (25℃)
OTHERS DIMENSION
17.5*90*54.5mm (W*H*D)
PACKING
78g;160pcs/13.5Kg/1.19CUFT
NOTE
℃







File Name:HDR-15-SPEC 2016-11-07