H B G - 1 6 0 P 160W Constant Voltage + Constant Current LED Driver
series
SPECIFICATION
MODEL
HBG-160P-36
HBG-160P-48
HBG-160P-60
OUTPUT
DC VOLTAGE
36V
48V
CONSTANT CURRENT REGION Note.2 21.6 ~ 36V
28.8 ~ 48V
RATED CURRENT
4.4A
3.3A
RATED POWER
Note.5 158.4W
158.4W
RIPPLE & NOISE (max.) Note.3 300mVp-p
300mVp-p
CURRENT ADJ. RANGE
Adjustable for A-Type only (via built-in potentiometer)
2.6 ~ 4.4A
1.98 ~ 3.3A
VOLTAGE TOLERANCE Note.4 ±2.0%
LINE REGULATION
±0.5%
LOAD REGULATION
±1.0%
SETUP, RISE TIME Note.6 2500ms, 200ms / 115VAC 500ms, 200ms / 230VAC
HOLD UP TIME (Typ.)
12ms/115VAC,230VAC
VOLTAGE RANGE
90 ~ 305VAC 127 ~ 431VDC
Note.5 (Please refer to "STATIC CHARACTERISTIC" section)
60V
36 ~ 60V
2.6A
156W
300mVp-p
1.6 ~ 2.6A
FREQUENCY RANGE
POWER FACTOR
47 ~ 63Hz
PF≧0.98/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
INPUT
TOTAL HARMONIC DISTORTION
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT(Typ.)
THD< 20%(@load≧60%/115VC,230VAC; @load≧75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
92%
93%
93.5%
1.7A / 115VAC 0.78A / 230VAC 0.7A / 277VAC
COLD START 65A(twidth=425μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
OVER CURRENT
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
<0.75mA / 277VAC
95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed
41 ~ 47V
54 ~ 62V
65 ~ 75V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
Shut down o/p voltage, recovers automatically after temperature goes down
Ta=-40 ~ +45℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
20 ~ 95% RH non-condensing
-40 ~ +80℃, 10 ~ 95% RH
±0.03%/℃ (0 ~ 45℃)
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY &
EMC
OTHERS
NOTE
SAFETY STANDARDS
UL8750,CSA C22.2 No.250.13-12; ENEC EN61347-1,EN61347-2-13,EN62384, GB19510.1,GB19510.14 approved
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to EN55015, EN61000-3-2 Class C (@load ≧60%) ; EN61000-3-3, GB17743, GB17625.1
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547,light industry level(surge immunity:Line-Earth:4KV,Line-Line:2KV)
MTBF
195.5Khrs min. MIL-HDBK-217F (25℃)
DIMENSION
Refer to mechanical specification
PACKING
0.4Kg; 36pcs/15.4Kg/1.35CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
2. Please refer to "DRIVING METHODS OF LED MODULE".
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
4. Tolerance : includes set up tolerance, line regulation and load regulation.
5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently
connected to the mains.
9. This series meets the typical life expectancy of >50,000 hours of operation when Ta is about 45℃ or less.
10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
File Name:HBG-160P-SPEC 2016-05-03