English
Language : 

GP25B Datasheet, PDF (2/3 Pages) Mean Well Enterprises Co., Ltd. – 25W AC-DC Triple Output Industrial Adaptor
25W AC-DC Triple Output Industrial Adaptor
GP25B series
SPECIFICATION
ORDER NO.
GP25B13A-R1B
GP25B13D-R1B
GP25B14E-R1B
OUTPUT
SAFETY MODEL NO.
GP25B13A
GP25B13D
DC VOLTAGE
Note.2 5V
12V
-5V
5V
12V
-12V
RATED SET CURRENT
2.5A
1.2A
0.3A
2.5A
1A
0.3A
CURRENT RANGE
0.5 ~ 2.5A 0.2 ~ 1.2A 0.1 ~ 0.3A 0.5 ~ 2.5A 0.2 ~ 1A 0.1 ~0.3A
RATED POWER
28.5W
28W
RIPPLE & NOISE (max.) Note.3 50mVp-p 100mVp-p 50mVp-p 60mVp-p 120mVp-p 50mVp-p
VOLTAGE TOLERANCE Note.4 ±5.0%
-5.0 ~ +10% ±3.0%
±5.0%
-5.0 ~ +5.0% ±3.0%
LINE REGULATION Note.5 ±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
LOAD REGULATION Note.6 ±5.0%
±5.0%
±3.0%
±5.0%
±5.0%
±3.0%
SETUP, RISE, HOLD UP TIME 800ms, 50ms, 20ms / 230VAC 1200ms, 50ms, 16ms / 115VAC at full load
GP25B14E
5V
2.5A
0.5 ~ 2.5A
29W
100mVp-p
±5.0%
±1.0%
±5.0%
15V
0.8A
0.1 ~ 0.8A
-15V
0.3A
0.1 ~ 0.3A
150mVp-p 50mVp-p
-5.0 ~ +15% ±3.0%
±1.0%
±1.0%
±5.0%
±3.0%
INPUT
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
90 ~ 264VAC 135~ 370VDC
47 ~ 63Hz
80%
80%
0.8A / 100VAC 0.4A / 230VAC
80.5%
INRUSH CURRENT (max.) 60A / 230VAC
LEAKAGE CURRENT (max.) 0.25mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
110 ~ 160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Clamp by zener diode(5V only), output short
WORKING TEMP.
-20 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03% / ℃ (0 ~ 40℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, CSA22.2, EN60950-1 approved
SAFETY &
EMC
(Note. 7)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
I/P-O/P:4242VDC
I/P-O/P,I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART15 / CISP22 class B
Compliance to EN61000-4-2,3,4,5,6,11, light industry level, criteria A
LIFE
3 years : 100% load 40℃, 8hours/day
MTBF
620K hrs min. MIL-HDBK-217F (25℃)
OTHERS
CONNECTOR
DIMENSION
PACKING
PLUG
CABLE
107.5*67*36mm (L*W*H)
0.3kg; 54pcs / 20kg / CARTON
See page 3
See page 3
NOTE
1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerence: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.When measured between the light load (20% of rated load) and full load, the load regulation is within ±5% whereas the cross regulation is within ±15%.
7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:GP25B-SPEC 2016-09-19