English
Language : 

ERPF-400 Datasheet, PDF (2/4 Pages) Mean Well Enterprises Co., Ltd. – 400W Single Output Switching Power Supply
400W Single Output Switching Power Supply
ERPF-400 series
SPECIFICATION
MODEL
ERPF-400-12
ERPF-400-24
ERPF-400-48
OUTPUT
DC VOLTAGE
12V
RATED CURRENT
30A
CURRENT RANGE Note.5 0 ~ 30A
RATED POWER
360W
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE
10.8 ~ 13.2V
VOLTAGE TOLERANCE Note.3 ±1.0%
LINE REGULATION
±0.5%
LOAD REGULATION
±0.5%
24V
16.7A
0 ~ 16.7A
400.8W
150mVp-p
21.6 ~ 26.4V
±1.0%
±0.5%
±0.5%
48V
8.3A
0 ~ 8.3A
398.4W
240mVp-p
43.2 ~ 52.8V
±1.0%
±0.5%
±0.5%
SETUP, RISE TIME
2000ms, 100ms/230VAC; 3000ms, 100ms/115VAC at full load
HOLD UP TIME (Typ.)
10ms/230VAC; 10ms/115VAC at full load
VOLTAGE RANGE Note.4
FREQUENCY RANGE
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
POWER FACTOR (Typ.)
PF≧0.95/230VAC, PF≧0.98/115VAC
INPUT
EFFICIENCY (Typ.)
89%
90%
91%
AC CURRENT (Typ.)
2.5A/230VAC 3A/115VAC
INRUSH CURRENT (Typ.)
cold start 45A/115VAC, 90A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC
OVER LOAD
SHORT CIRCUIT
PROTECTION OVER VOLTAGE
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Constant current limiting, recovers automatically after fault condition is removed
13.8 ~ 16.2V
27.6 ~ 32.4V
55.2 ~ 64.8V
Protection type :Shut down O/P voltage, re-power on to recover
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note.6) EMC EMISSION
Shut down O/P voltage, recovers automatically after temperature goes down
-30 ~ +60℃ (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-30 ~ +85℃, 10 ~ 95% RH
±0.1%/℃ (0 ~ 35℃)
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
IEC/EN 60950-1,CCC GB4943.1-2011 approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/ 70% RH
Compliance to EN55022 (CISPR22) class A, GB9254 classA, GB17625.1; EN61000-3-2
EMC IMMUNITY
Compliance to EN61000-4-5;light industry level,criteria A
OTHERS
NOTE
MTBF
233.422Khrs min. MIL-HDBK-217F (25℃)
DIMENSION
220.4*130*48mm (L*W*H)
PACKING
1.1Kg; 9pcs / 11Kg / 0.63CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. Please refer to “Static Characteristics".
6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 450mm*450mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com).
File Name:ERPF-400-SPEC 2017-08-14