SPECIFICATION
MODEL
DRC-40A
DRC-40B
OUTPUT NUMBER
CH1
CH2
CH1
CH2
DC VOLTAGE
13.8V
13.8V
27.6V
27.6V
RATED CURRENT
1.9A
1A
0.95A
0.5A
CURRENT RANGE
0 ~ 2.9A
--------
0 ~ 1.45A
--------
RATED POWER
40.02W
40.02W
RIPPLE & NOISE (max.) Note.2 120mVp-p
OUTPUT
VOLTAGE ADJ. RANGE CH1:12 ~ 15V
--------
200mVp-p
CH1:24 ~ 30V
--------
VOLTAGE TOLERANCE Note.3 ±1.0%
--------
±1.0%
--------
LINE REGULATION
±0.5%
--------
±0.5%
--------
LOAD REGULATION
±0.5%
--------
±0.5%
--------
SETUP, RISE TIME Note.4 400ms, 50ms/230VAC 800ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.) 50ms/230VAC 10ms/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)]
FREQUENCY RANGE 47 ~ 63Hz
INPUT EFFICIENCY (Typ.)
86%
87%
AC CURRENT (Typ.)
0.8A/115VAC 0.6A/230VAC
INRUSH CURRENT (Typ.) COLD START 30A/115VAC 60A/230VAC
OVERLOAD
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
OVER VOLTAGE
CH1:14.49 ~ 18.63V
CH1:28.98 ~ 37.26V
Protection type : Shut down o/p voltage, re-power on to recover
BATTERY CUT OFF
10±0.5V
20±1V
AC OK
Open collector output, CONTACT : AC OK ; CUT OFF : AC Fail ; max. rating : 50V/30mA
FUNCTION
BATTERY LOW
Open collector output, CUT OFF : Battery ; CONTACT : Battery Low ; max. rating : 50V/30mA
Battery low voltage : < 11V
Battery low voltage : < 22V
WORKING TEMP.
WORKING HUMIDITY
-30 ~ +70℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 55℃) on CH1 output
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved
SAFETY & WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
EMC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
(Note 5)
EMC EMISSION
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61204-3, light industry level, criteria A
MTBF
536.6K hrs min. MIL-HDBK-217F (25℃)
OTHERS DIMENSION
40*90*100mm (W*H*D)
PACKING
0.3Kg; 42pcs/13.6Kg/0.82CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed
that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power
supplies.” (as available on http://www.meanwell.com)
6. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded
permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.
File Name:DRC-40-SPEC 2015-03-12