DRA-40 Datasheet, PDF (2/5 Pages) Mean Well Enterprises Co., Ltd. – UNIVERSAL AC INPUT/FULL RANGE
40W Single Output Switching Power Supply
DRA-40 series
SPECIFICATION
MODEL
DRA-40-12
DRA-40-24
DC VOLTAGE
12V
24V
CONSTANT CURRENT REGION 3~12V
3~24V
RATED CURRENT
3.34A
1.7A
CURRENT RANGE
0 ~ 3.34A
0 ~ 1.7A
RATED POWER
40.08W
40.8W
RIPPLE & NOISE (max.) Note.2 120mVp-p
150mVp-p
OUTPUT VOLTAGE ADJ. RANGE 12 ~ 15V
24 ~ 30V
VOLTAGE TOLERANCE Note.3 ±1.0%
±1.0%
LINE REGULATION
±0.5%
±0.5%
LOAD REGULATION
±0.5%
±0.5%
SETUP, RISE TIME Note.4 400ms, 90ms/230VAC 800ms, 90ms/115VAC at full load
HOLD UP TIME (Typ.) 50ms/230VAC 10ms/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)]
FREQUENCY RANGE 47 ~ 63Hz
INPUT EFFICIENCY (Typ.)
85%
87%
AC CURRENT (Typ.)
0.8A/115VAC 0.6A/230VAC
INRUSH CURRENT (Typ.) COLD START 30A/115VAC 60A/230VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
95 ~ 108% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
14.49 ~ 18.63V
28.98 ~ 37.26V
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-30 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 55℃) on output
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved
SAFETY & WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
EMC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
(Note 5)
EMC EMISSION
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61204-3, light industry level, criteria A
MTBF
439.3K hrs min. MIL-HDBK-217F (25℃)
OTHERS DIMENSION
40*90*100mm (W*H*D)
NOTE
PACKING
0.3Kg; 42pcs/13.6Kg/0.82CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed
that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power
supplies.” (as available on http://www.meanwell.com)
6. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded
permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.
File Name:DRA-40-SPEC 2015-06-11