English
Language : 

YP-350J-AA Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 350WATX with 24V industrial PC Power Supply
350W ATX with 24V industrial PC Power Supply
YP-350J-AA
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage
Power good and fail signal
FAN speed control function
Power ON-OFF switch with indicator
Forced air cooling by built-in DC fan
100% full load burn-in test
Approvals: UL / CUL / TUV / CB / FCC / CE
2 years warranty
SPECIFICATION
ORDER NO.
YP-350J-AA
SAFETY MODEL NO.
YP-350J
CHANNEL
CH1
CH2
CH3
CH4
CH5
CH6
STANDBY
DC VOLTAGE
3.3V
5V
12V
24V
-5V
-12V
5VSB
MINIMUM CURRENT
0.3A
0.1A
0A
0A
0A
0A
0A
RATED CURRENT
9A
15A
9A
5A
0.3A
0.8A
2.0A
MAXIMUM CURRENT
14A
21A
15A
5A
OUTPUT COMBINE LOAD
135W max. For +5V and +3.3V output
210W max. For +5V, +3.3V and +12V output
0.3A
0.8A
2.0A
RATED POWER (max.)
350W continue load
RIPPLE & NOISE (max.) Note.2 50mVp-p
LINE REGULATION
1.0%
50mVp-p
1.0%
120mVp-p
1.0%
150mVp-p
1.0%
100mVp-p
2.0%
120mVp-p
2.0%
50mVp-p
1.0%
LOAD REGULATION Note.3 5.0%
5.0%
-2.0 ~ +8.0% -2.0 ~ +8.0%
5.0%
10%
5.0%
HOLD UP TIME
10ms min. at full load (Rated current)
INPUT
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
EFFICIENCY (Typ.)
100 ~ 264VAC
47 ~ 63Hz
PF>0.95@230VAC
70%
PF>0.98@115VAC
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT
OVERLOAD
8.0A / 115VAC 4.5A / 230VAC
40A / 115VAC 80A / 230VAC
3.5mA / 240VAC
105 ~ 180% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
PROTECTION OVER VOLTAGE
110% ~ 130% of rated voltage for +3.3V, +5V and +12V
Protection type : Shut down o/p voltage, re-power on to recover
SHORT CIRCUIT
All output equipped with short circuit
Protection type : Shut down o/p voltage, re-power on to recover
POWER GOOD SIGNAL
FUNCTION POWER FAIL SIGNAL
The TTL compatible signal out with 100ms to 500ms delay after power set up
The TTL compatible signal will go down at least 1ms before +5V below 4.75V
PS-ON INPUT SIGNAL
Power on: PS-ON = "Low" or "<0.8V" ; Power off: PS-ON = "Hi" or ">2V"
WORKING TEMP.
-10 ~ +40
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.05% / (0 ~ 50 )
VIBRATION
10 ~ 200Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:1.5KVAC
I/P-O/P: 50M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) class B, FCC part 15 Class B
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4, 5,6,8,11, light industry level, criteria A
MTBF
100K hrs min.
OTHERS
CONNECTOR
COOLING
DIMENSION
PACKING
ATX main power connector * 1ea; +12V power connector * 1ea; Auxiliary power connector * 1ea
Peripheral power connector * 5 ea; Floppy drive power connector * 2 ea
Forced air ventilation by 8cmx8 ball bearing DC fan
171*150*86mm (L*W*H)
1.6Kg ; 12pcs / 20Kg / CARTON
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Line regulation is measured from low line to high line at rated load.
4. Load regulation is measured from 20% to 100% max. Load.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name: YP-350J-AA-SPEC 2010-02-25