English
Language : 

USP-225_10 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 225W Single Output with PFC Function
225W Single Output with PFC Function
USP-225 series
Features :
Universal AC input / Full range
Built in active PFC circuit compliance to EN61000-3-2
Protections: Short circuit / Overload / Over voltage / Over temperature
Free air convection for 150W and forced air convection for 225W
High power density 4.7w/in3
Active AC surge current limiting
U-bracket low profile:38mm
3 years warranty
SPECIFICATION
MODEL
USP-225-3.3
USP-225-5
USP-225-12
USP-225-15
USP-225-24
USP-225-48
OUTPUT
DC VOLTAGE
3.3V
5V
12V
RATED CURRENT
40A
40A
18.7A
CURRENT RANGE
0 ~ 40A
0 ~ 40A
0 ~ 18.7A
RATED POWER
132W
200W
224.4W
RIPPLE & NOISE (max.) Note.2 100mVp-p
100mVp-p
100mVp-p
VOLTAGE ADJ. RANGE
2.97 ~ 3.6V
4.5 ~ 5.5V
10.8 ~ 13.2V
VOLTAGE TOLERANCE Note.3 2.0%
2.0%
2.0%
LINE REGULATION
0.5%
0.5%
0.5%
LOAD REGULATION
1.0%
1.0%
1.0%
SETUP, RISE TIME
500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)
22ms/230VAC 22ms/115VAC at full load
15V
15A
0 ~ 15A
225W
100mVp-p
13.5 ~ 16.5V
2.0%
0.5%
1.0%
24V
9.4A
0 ~ 9.4A
225.6W
150mVp-p
21.6 ~ 26.4V
2.0%
0.5%
1.0%
48V
4.7A
0 ~ 4.7A
225.6W
250mVp-p
43.2 ~ 52.8V
2.0%
0.5%
1.0%
VOLTAGE RANGE
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.93/230VAC PF>0.97/115VAC at full load
INPUT
EFFICIENCY (Typ.)
72%
77%
83%
84%
85%
86%
AC CURRENT 115VAC 2.2A
3.3A
(Typ.)
230VAC 1.1A
1.6A
INRUSH CURRENT (Typ.) 15A/115VAC 30A/230VAC
LEAKAGE CURRENT
<3.5mA / 240VAC
OVERLOAD
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
3.6 ~ 4.4V
5.5 ~ 7.4V
13.2 ~ 16.3V
16.5 ~ 20.2V
Protection type : Shut down o/p voltage, re-power on to recover
26.4 ~ 32.4V
52.8 ~ 64.8V
OVER TEMPERATURE
95 5 (RTH2 : detect on heatsink of power transistor)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
WORKING HUMIDITY
-20 ~ +65 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light industry level, criteria A
220K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
PACKING
202*101.5*38mm (L*W*H)
0.85Kg; 16pcs/14.6Kg/0.76CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:USP-225-SPEC 2010-10-18