English
Language : 

USP-150_12 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 150W U-Bracket Single Output with PFC Function
150W U-Bracket Single Output with PFC Function
USP-150 series
Features :
Universal AC input / Full range(up to 295VAC)
Built in active PFC function
Constant Voltage design
High efficiency up to 93%
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
U-bracket low profile:33mm
ZVS technology to reduce power dissipation
3 years warranty
SPECIFICATION
MODEL
USP-150-12
USP-150-15
USP-150-24
USP-150-36
USP-150-48
DC VOLTAGE
12V
15V
24V
36V
RATED CURRENT
12.5A
10A
6.3A
4.2A
CURRENT RANGE
0 ~ 12.5A
0 ~ 10A
0 ~ 6.3A
0 ~ 4.2A
RATED POWER
150W
150W
151.2W
151.2W
OUTPUT RIPPLE & NOISE (max.) Note.2 100mVp-p
150mVp-p
150mVp-p
250mVp-p
VOLTAGE ADJ. RANGE
11.0~13.2V
13.5~16.5V
21.6~26.4V
32.4~39.6V
VOLTAGE TOLERANCE Note.3 2.0%
2.0%
2.0%
2.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
1.0%
1.0%
1.0%
1.0%
SETUP, RISE TIME
2000ms, 100ms/230VAC 3000ms, 100ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE Note.4 90 ~ 295VAC 127 ~ 417VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
PF 0.98/115VAC
91.5%
PF 0.96/230VAC PF 0.94/277VAC at full load
91.5%
93%
93%
AC CURRENT (Typ.)
2A/115VAC 1A/230VAC 0.7A/277VAC
INRUSH CURRENT (Typ.) Cold start 65A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
130~185% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
13.6 ~ 16.3V
17 ~ 21V
26.7 ~ 32.4V
41.4 ~ 48.6V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
OVER TEMPERATURE
100 5 (RTH2)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP
-30 ~ +65 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 60
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
Design refer to IEC60950-1,EN60950-1,UL60950-1
SAFETY & WITHSTAND VOLTAGE Note.6 I/P-O/P:3.0KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
EMC
(Note 5)
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25 / 70%RH
Compliance to EN55022 (CISPR22) Class B,EN61000-3-2,EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024, light industry level (surge 4KV), criteria A
48V
3.2A
0 ~ 3.2A
153.6W
250mVp-p
43.2~52.8V
2.0%
0.5%
1.0%
93%
53 ~ 64.8V
OTHERS
MTBF
DIMENSION
PACKING
216.3K hrs min. MIL-HDBK-217F (25 )
215*67.4*33mm (L*W*H)
0.48kg; 24PCS/12.5kg/0.61CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Please remove the component D1 before conducted Hipot test.
File Name:USP-150-SPEC 2012-02-04