English
Language : 

USP-150 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 150W U-Bracket Single Output with PFC Function
150W U-Bracket Single Output with PFC Function
USP-150 series
Features :
Universal AC input / Full range(up to 295VAC)
Built in active PFC function
Constant Voltage design
High efficiency up to 93%
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
U-bracket low profile:33mm
ZVS technology to reduce power dissipation
3 years warranty
SPECIFICATION
MODEL
USP-150-12
USP-150-15
USP-150-24
USP-150-36
USP-150-48
OUTPUT
DC VOLTAGE
12V
RATED CURRENT
12.5A
CURRENT RANGE
0 ~ 12.5A
RATED POWER
150W
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE ADJ. RANGE
11.0~13.2V
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
0.5%
LOAD REGULATION
1.0%
15V
10A
0 ~ 10A
150W
150mVp-p
13.5~16.5V
2.0%
0.5%
1.0%
24V
6.3A
0 ~ 6.3A
151.2W
150mVp-p
21.6~26.4V
2.0%
0.5%
1.0%
36V
4.2A
0 ~ 4.2A
151.2W
250mVp-p
32.4~39.6V
2.0%
0.5%
1.0%
48V
3.2A
0 ~ 3.2A
153.6W
250mVp-p
43.2~52.8V
2.0%
0.5%
1.0%
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
2000ms, 100ms/230VAC 3000ms, 100ms/115VAC at full load
16ms/230VAC 16ms/115VAC at full load
Note.4 90 ~ 295VAC 127 ~ 417VDC
47 ~ 63Hz
POWER FACTOR (Typ.)
PF 0.96/230VAC PF 0.98/115VAC at full load
INPUT
EFFICIENCY (Typ.)
91.5%
91.5%
93%
93%
93%
AC CURRENT (Typ.)
2A/115VAC 1A/230VAC
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
Cold start 65A/230VAC
<2mA / 240VAC
OVERLOAD
SHORT CIRCUIT
110~160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
13.6 ~ 16.3V
17 ~ 21V
26.7 ~ 32.4V
41.4 ~ 48.6V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
100 5 (RTH2)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
53 ~ 64.8V
WORKING TEMP
-30 ~ +65 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 60
VIBRATION
SAFETY STANDARDS
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
Design refer to IEC60950-1,EN60950-1,UL60950-1
SAFETY &
EMC
(Note 5)
OTHERS
WITHSTAND VOLTAGE Note.6 I/P-O/P:3.0KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25 / 70%RH
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,EN61000-3-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level (surge 4KV), criteria A
MTBF
216.3K hrs min. MIL-HDBK-217F (25 )
DIMENSION
215*67.4*33mm (L*W*H)
PACKING
0.48kg; 24PCS/12.5kg/0.61CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Please remove the component D1 before conducted Hipot test.
File Name:USP-150-SPEC 2011-03-25