English
Language : 

ULP-150_1108 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 150W U-Bracket Single Output with PFC Function
150W U-Bracket Single Output with PFC Function
ULP-150 series
■ Features :
Universal AC input / Full range(up to 295VAC)
Built in active PFC compliance to EN61000-3-2 class C
Constant Voltage design
High efficiency up to 93%
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Half encapsulated
U-bracket low profile:33mm
ZVS technology to reduce power dissipation
SPECIFICATION
MODEL
DC VOLTAGE
ULP-150-12
12V
Suitable for built-in type LED applications
ULP-150-15
ULP-150-24
3 years warranty
15V
24V
ULP-150-36
36V
ULP-150-48
48V
RATED CURRENT
12.5A
10A
6.3A
4.2A
3.2A
CURRENT RANGE
0 ~ 12.5A
0 ~ 10A
0 ~ 6.3A
0 ~ 4.2A
0 ~ 3.2A
RATED POWER
150W
150W
151.2W
151.2W
153.6W
RIPPLE & NOISE (max.) Note.2 100mVp-p
150mVp-p
150mVp-p
250mVp-p
250mVp-p
OUTPUT VOLTAGE ADJ. RANGE
11.0~13.2V
13.5~16.5V
21.6~26.4V
32.4~39.6V
43.2~52.8V
VOLTAGE TOLERANCE Note.3 ± 2.0%
± 2.0%
± 2.0%
± 2.0%
± 2.0%
LINE REGULATION
± 0.5%
± 0.5%
± 0.5%
± 0.5%
± 0.5%
LOAD REGULATION
± 1.0%
± 1.0%
± 1.0%
± 1.0%
± 1.0%
SETUP, RISE TIME
2000ms, 100ms/230VAC 3000ms, 100ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE Note.4 90 ~ 295VAC 127 ~ 417VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.98/115VAC PF>0.96/230VAC PF>0.94/277VAC at full load
INPUT
EFFICIENCY (Typ.)
91.5%
91.5%
93%
93%
93%
AC CURRENT (Typ.)
2A/115VAC 1A/230VAC 0.7A/277VAC
INRUSH CURRENT (Typ.) Cold start 65A/230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
OVERLOAD
130~185% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
13.6 ~ 16.3V
17 ~ 21V
26.7 ~ 32.4V
41.4 ~ 48.6V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
53 ~ 64.8V
OVER TEMPERATURE
95℃± 5℃(RTH2)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
-30 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
± 0.03%/℃ (0 ~ 60℃)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
Design refer to EN61347-2-13,IEC61347-2-13,UL8750
SAFETY &
EMC
(Note 5)
WITHSTAND VOLTAGE Note.6
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25℃/ 70%RH
Compliance to EN55015, EN61000-3-2 Class C(≡60% load),EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
MTBF
OTHERS DIMENSION
216.3K hrs min. MIL-HDBK-217F (25℃)
215*67.4*33mm (L*W*H)
PACKING
0.67kg; 24PCS/17.5kg/0.65CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Please remove the component D1 before conducted Hipot test.
File Name:ULP-150-SPEC 2011-08-11