ULP-150 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 150W U-Bracket Single Output with PFC Function
150W U-Bracket Single Output with PFC Function
ULP-150 series
Features :
Universal AC input / Full range(up to 295VAC)
Built in active PFC compliance to EN61000-3-2 class C
Constant Voltage design
High efficiency up to 93%
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Half encapsulated
U-bracket low profile:33mm
ZVS technology to reduce power dissipation
Suitable for built-in type LED applications
3 years warranty
SPECIFICATION
MODEL
ULP-150-12
ULP-150-15
ULP-150-24
ULP-150-36
ULP-150-48
OUTPUT
DC VOLTAGE
12V
15V
24V
RATED CURRENT
12.5A
10A
6.3A
CURRENT RANGE
0 ~ 12.5A
0 ~ 10A
0 ~ 6.3A
RATED POWER
150W
150W
151.2W
RIPPLE & NOISE (max.) Note.2 100mVp-p
150mVp-p
150mVp-p
VOLTAGE ADJ. RANGE
11.0~13.2V
13.5~16.5V
21.6~26.4V
VOLTAGE TOLERANCE Note.3 2.0%
2.0%
2.0%
LINE REGULATION
0.5%
0.5%
0.5%
LOAD REGULATION
1.0%
1.0%
1.0%
SETUP, RISE TIME
2000ms, 100ms/230VAC 3000ms, 100ms/115VAC at full load
36V
4.2A
0 ~ 4.2A
151.2W
250mVp-p
32.4~39.6V
2.0%
0.5%
1.0%
48V
3.2A
0 ~ 3.2A
153.6W
250mVp-p
43.2~52.8V
2.0%
0.5%
1.0%
HOLD UP TIME (Typ.)
16ms/230VAC
VOLTAGE RANGE Note.4 90 ~ 295VAC
FREQUENCY RANGE
47 ~ 63Hz
16ms/115VAC at full load
127 ~ 417VDC
INPUT
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
PF 0.96/230VAC PF 0.98/115VAC
91.5%
91.5%
2A/115VAC 1A/230VAC
Cold start 65A/230VAC
PF 0.94/277VAC at full load; PF 0.9/230VAC at 50%~100% load
93%
93%
93%
LEAKAGE CURRENT
<0.75mA / 277VAC
OVERLOAD
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
130~185% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
13.6 ~ 16.3V
17 ~ 21V
26.7 ~ 32.4V
41.4 ~ 48.6V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
95 5 (RTH2)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
53 ~ 64.8V
WORKING TEMP.
-30 ~ +70 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 60
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
Design refer to EN61347-2-13,IEC61347-2-13,UL8750
SAFETY &
EMC
(Note 5)
WITHSTAND VOLTAGE Note.6 I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25 / 70%RH
EMI CONDUCTION & RADIATION Compliance to EN55015 Class B
HARMONIC CURRENT
Compliance to EN61000-3-2 Class C( 60% load),EN61000-3-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level (surge 4KV), criteria A
OTHERS
NOTE
MTBF
216.3K hrs min. MIL-HDBK-217F (25 )
DIMENSION
215*67.4*33mm (L*W*H)
PACKING
0.67kg; 24PCS/17.5kg/0.65CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Please remove the component D1 before conducted Hipot test.
File Name:ULP-150-SPEC 2011-02-23