English
Language : 

TS-3000 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 3000W True Sine Wave DC-AC Power Inverter
3000W True Sine Wave DC-AC Power Inverter
TS-3000 series
Features :
True sine wave output (THD<3%)
High surge power up to 6000W
High efficiency up to 92%
Power ON-OFF switch
Standby saving mode can be selectable
Front panel indicator for operation status
Thermostatically controlled cooling fan
SPECIFICATION
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Input polarity reverse / Overload
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
Optional monitoring software
3 years warranty
E13
MODEL
TS-3000-112
TS-3000-124
TS-3000-148
TS-3000-212
TS-3000-224
TS-3000-248
RATED POWER (Typ.)
3000W
3000W
3000W
3000W
3000W
3000W
MAXIMUM OUTPUT POWER 3450W for 180 sec. / 4500W for 10 sec. / surge power 6000W for 30 cycles
AC VOLTAGE
100 / 110 / 115 / 120VAC selectable by setting button
200 / 220 / 230 / 240VAC selectable by setting button
FREQUENCY
OUTPUT
WAVEFORM
60 0.1Hz 50/60Hz selectable by setting button S.W
True sine wave (THD<3%) at rated input voltage
50 0.1Hz 50/60Hz selectable by setting button S.W
AC REGULATION (Typ.)
3%
SAVING MODE (Typ.)
Load 5W will be changed to standby mode
FRONT PANEL INDICATOR Battery voltage level, output load level, saving mode, fault and operation status
BAT. VOLTAGE
12V
24V
48V
12V
24V
48V
INPUT
VOLTAGE RANGE (Typ.)Note.1 10.5 ~ 15VDC
21 ~ 30VDC
DC CURRENT (Typ.) Note.5 300A
150A
NO LOAD DISSIPATION (Typ.) 10W @ standby saving mode
42 ~ 60VDC
75A
10.5 ~ 15VDC
300A
21 ~ 30VDC
150A
42 ~ 60VDC
75A
OFF MODE CURRENT DRAW 1mA
EFFICIENCY (Typ.) Note.2 88%
90%
91%
89%
91%
92%
BATTERY TYPES
Open & sealed Lead Acid
FUSE
BATTERY BAT. LOW ALARM
INPUT
PROTECTION
BAT. LOW SHUTDOWN
BAT. POLARITY
80A*5
40A*5
11.3 4%
22.5 4%
10.5 4%
21 4%
By internal fuse open
30A*3
45 4%
42 4%
80A*5
11.3 4%
10.5 4%
40A*5
22.5 4%
21 4%
30A*3
45 4%
42 4%
OVER TEMPERATURE
105 5
95 5
95 5
90 5
85 5
85 5
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH3 detect on heatsink of power transistor
OUTPUT SHORT
OUTPUT
PROTECTION OVER LOAD (Typ.)
Protection type : Shut down o/p voltage, re-power on to recover
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
CIRCUIT BREAKER
AC output receptacle : 15A
GFCI PROCTECTION
Optional (Only type F)
None
WORKING TEMP.
Note.3 0 ~ +40 @ 100% load ; 60 @ 50% load
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT
STORAGE TEMP., HUMIDITY -30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH
VIBRATION
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL458 (only for "GFCI" receptacle-Type F ) None
SAFETY & LVD
None
EMC
WITHSTAND VOLTAGE
Bat I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
EMI CONDUCTION&RADIATION Compliance to FCC class A
EN60950-1
Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
EMS IMMUNITY
None
Compliance to EN61000-4-2,3,8 ENV50204
OTHERS
NOTE
CONTROL WIRING
RJ11 -RS232 (Option)
DIMENSION
466.8*283.5*100mm (L*W*H)
PACKING
11.9Kg; 1pcs/13Kg/1.98CUFT
1.Efficiency is tested by 2100W, linear load at 13V, 26V, 52V input voltage.
2.Output derating capacity referenced by curve 1.
3.DC current is tested by 3000W, linear load at 12V, 24V, 48V input voltage.
4.All parameters not specified above are measured at rated load, 25 of ambient temperature.
5.The tolerance of each voltage value by models is:112/212 0.5V;124/224 1V;148/248 2V
File Name:TS-3000-SPEC 2009-04-09