English
Language : 

TP-75_10 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 75W Triple Output with PFC Function
75W Triple Output with PFC Function
TP-75 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage
Low profile: 33mm thickness
LED indicator for power on
Cooling by free air convection
Fixed switching frequency at PFC:67KHz PWM:134KHz
3 years warranty
SPECIFICATION
MODEL
TP-75A
TP-75B
TP-75C
OUTPUT NUMBER
CH1
CH2
CH3
CH1
CH2
CH3
CH1
CH2
CH3
DC VOLTAGE
5V
12V
-5V
5V
12V
-12V
5V
15V
-15V
RATED CURRENT
7A
3A
0.6A
7A
3A
0.4A
6A
2.5A
0.5A
CURRENT RANGE
1.5 ~ 10A 0.2 ~ 4A 0 ~ 0.6A 1.5 ~ 10A 0.2 ~ 4A 0 ~ 0.6A 1.5 ~ 10A 0.2 ~ 3A 0 ~ 0.6A
RATED POWER
74W
75.8W
75W
RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 100mVp-p 100mVp-p 120mVp-p 120mVp-p 100mVp-p 120mVp-p 120mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 3.0%
4.0%
8.0%
3.0%
4.0%
8.0%
3.0%
4.0%
8.0%
LINE REGULATION
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION
3.0%
4.0%
8.0%
3.0%
4.0%
8.0%
3.0%
4.0%
8.0%
SETUP, RISE TIME
800ms, 60ms at full load
HOLD UP TIME (Typ.)
36ms at full load
VOLTAGE RANGE Note.5 90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
127 ~ 370VDC
INPUT
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
PF>0.95/230VAC
70%
PF>0.98/115VAC at full load
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.5A/115VAC 0.8A/115VAC
COLD START 20A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75V on +5V
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-10 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1min.
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
MTBF
198.4K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
179*99*33mm (L*W*H)
PACKING
0.65Kg; 20pcs/12.7Kg/0.64CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:TP-75-SPEC 2010-10-18