English
Language : 

TN-3000_1105 Datasheet, PDF (1/4 Pages) Mean Well Enterprises Co., Ltd. – 3000W True Sine Wave DC-AC Inverter with Solar Charger
3000W True Sine Wave DC-AC Inverter with Solar Charger
TN-3000 series
SPECIFICATION
Features :
True sine wave output (THD<3%)
High surge power up to 6000W
U.P.S. mode and energy saving mode (selectable)
High efficiency up to 92%
Power ON-OFF switch
Standby saving mode can be selectable
Front panel indicator for operation status
Thermostatically controlled cooling fan
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Input polarity reverse / Overload / AC circuit breaker
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
Built-in solar / AC charger
Optional monitoring software and connection cable
(MW order No.: DS-TN-1500)
3 years warranty
E13
MODEL
TN-3000-112
TN-3000-124
TN-3000-148
TN-3000-212
TN-3000-224
TN-3000-248
RATED POWER (Typ.)
3000W
MAXIMUM OUTPUT POWER (Typ.) 3450W for 180 sec. / 4500W for 10 sec. / surge power 6000W for 30 cycles
AC VOLTAGE
Factory setting set at 110VAC
100 / 110 / 115 / 120VAC selectable by setting button S.W
Factory setting set at 230VAC
200 / 220 / 230 / 240VAC selectable by setting button S.W
OUTPUT
FREQUENCY
WAVEFORM
60 0.1Hz 50/60Hz selectable by setting button S.W
True sine wave (THD<3%) at rated input voltage
50 0.1Hz 50/60Hz selectable by setting button S.W
AC REGULATION (Typ.)
3%
TRANSFER TIME (Typ.)
10ms inverter by pass
SAVING MODE (Typ.)
Default disabled. Load 5W will be changed to standby mode
FRONT PANEL INDICATOR Battery voltage level, output load level, saving mode, fault and operation status
BAT. VOLTAGE
12V
24V
48V
12V
24V
48V
VOLTAGE RANGE (Typ.) Note.3,6 10.5 ~ 15VDC
21 ~ 30VDC
42 ~ 60VDC
10.5 ~ 15VDC
21 ~ 30VDC
42 ~ 60VDC
DC CURRENT (Typ.) Note.4 300A
150A
75A
300A
150A
75A
INPUT
NO LOAD DISSIPATION (Typ.) 10W @ standby saving mode
OFF MODE CURRENT DRAW (Typ.) 1mA
EFFICIENCY (Typ.) Note.1 88%
90%
91%
89%
91%
92%
BATTERY TYPES
Open & sealed lead acid battery
FUSE
40A*12
40A*6
BATTERY BAT. LOW ALARM
Note.6 11.3V
INPUT
PROTECTION BAT. LOW SHUTDOWN Note.6 10.5V
22.5V
21V
REVERSE POLARITY
By internal fuse open
20A*6
45V
42V
40A*12
11.3V
10.5V
40A*6
22.5V
21V
20A*6
45V
42V
OVER TEMPERATURE
90 5
85 5
85 5
80 5
Protection type : Shut down o/p voltage, re-power on to recover
75 5
75 5
OUTPUT SHORT
OUTPUT
PROTECTION OVER LOAD (Typ.)
Protection type : Shut down o/p voltage, re-power on to recover
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
CIRCUIT BREAKER
AC output: 40A, AC receptacle:15A
AC output: 20A, AC receptacle: 15A
GFCI PROCTECTION
Optional (Only type F)
WORKING TEMP.
Note.2 0 ~ +40 @ 100% load ; 60 @ 50% load
None
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT
STORAGE TEMP., HUMIDITY -30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH
VIBRATION
SAFETY STANDARDS
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
UL458 (only for "GFCI" receptacle-Type F ) None
LVD
SAFETY & WITHSTAND VOLTAGE
None
EN60950-1
Bat I/P - AC I/P:3.0KVAC Bat I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
EMC
ISOLATION RESISTANCE Bat I/P - AC O/P, Bat I/P - FG, AC O/P - FG: 100M ohms / 500VDC / 25 / 70% RH
EMC EMISSION
EMC IMMUNITY
Compliance to FCC class A
None
Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
Compliance to EN61000-4-2,3,4,5,6,8,11
AC
CHARGE CURRENT (Typ.) 25A
12A
6A
CHARGER CHARGE VOLTAGE Note.6 14.3V
28.5V
57V
25A
12A
6A
14.3V
28.5V
57V
SOLAR MAX OPEN CIRCUIT VOLTAGE 25V
45V
75V
25V
45V
75V
PANEL
SHORT CIRCUIT CURRENT (max.) 30A
CONTROL WIRING
RJ11 -RS232 (Option)
OTHERS DIMENSION
PACKING
466.8*283.5*100mm (L*W*H)
12.9Kg; 1pcs/14Kg/1.98CUFT
NOTE
1.Efficiency is tested by 2100W, linear load at 13V, 26V, 52V input voltage.
2.Output derating capacity referenced by curve 1.
3.Output derating capacity referenced by curve 2.
4.DC current is tested by 3000W, linear load at 12V, 24V, 48V input voltage.
5.All parameters not specified above are measured at rated load, 25 of ambient temperature.
6.The tolerance of each voltage value by models is:112/212 0.5V;124/224 1V;148/248 2V
File Name:TN-3000-SPEC 2011-05-24