English
Language : 

TN-1500_12 Datasheet, PDF (1/4 Pages) Mean Well Enterprises Co., Ltd. – 1500W True Sine Wave DC-AC Inverter with Solar Charger
1500W True Sine Wave DC-AC Inverter with Solar Charger
TN-1500 series
SPECIFICATION
Features :
True sine wave output (THD<3%)
High surge power up to 3000W
U.P.S. mode and energy saving mode (selectable)
High efficiency up to 91%
Power ON-OFF switch
Standby saving mode can be selectable
Front panel indicator for operation status
Thermostatically controlled cooling fan
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Input polarity reverse / Overload / AC circuit breaker
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
Built-in solar / AC charger
Optional monitoring software
3 years warranty
E13
MODEL
TN-1500-112
TN-1500-124
TN-1500-148
TN-1500-212
TN-1500-224
TN-1500-248
RATED POWER (Typ.)
1500W
MAXIMUM OUTPUT POWER (Typ.) 1725W for 180 sec. / 2250W for 10 sec. / surge power 3000W for 30 cycles
AC VOLTAGE
Factory setting set at 110VAC
100 / 110 / 115 / 120VAC selectable by setting button S.W
Factory setting set at 230VAC
200 / 220 / 230 / 240VAC selectable by setting button S.W
FREQUENCY
60 0.1Hz 50/60Hz selectable by setting button S.W
50 0.1%Hz 50/60Hz selectable by setting button S.W
OUTPUT WAVEFORM
Note.2 True sine wave (THD<3%) at rated input voltage
AC REGULATION (Typ.)
3.0%
TRANSFER TIME (Typ.)
10ms inverter by pass
SAVING MODE (Typ.)
Default disabled. Load 5W will be changed to standby mode
FRONT PANEL INDICATOR Battery voltage level, output load level, saving mode, fault and operation status
BAT. VOLTAGE
12V
24V
48V
12V
24V
48V
VOLTAGE RANGE (Typ.)Note.1 10.5 ~ 15VDC
21 ~ 30VDC
42 ~ 60VDC
10.5 ~ 15VDC
21 ~ 30VDC
42 ~ 60VDC
DC CURRENT (Typ.) Note.5 150A
75A
37.5A
150A
75A
37.5A
INPUT
NO LOAD DISSIPATION
18W @ standby saving mode
OFF MODE CURRENT DRAW 1mA
EFFICIENCY (Typ.) Note.2 87%
89%
89%
88%
90%
91%
BATTERY TYPES
Open & sealed Lead Acid
FUSE
BATTERY BAT. LOW ALARM
INPUT
PROTECTION
BAT. LOW SHUTDOWN
REVERSE POLARITY
40A*5
30A*3
11.3 4%
22.5 4%
10.5 4%
21 4%
By internal fuse open
30A*2
45 4%
42 4%
40A*5
11.3 4%
10.5 4%
30A*3
22.5 4%
21 4%
30A*2
45 4%
42 4%
OVER TEMPERATURE
82 5
82 5
96 5
68 5
68 5
68 5
Protection type : Shut down o/p voltage, re-power on to recover ; by internal RTH3 detect on heatsink of power transistor
OUTPUT SHORT
OUTPUT
PROTECTION OVER LOAD (Typ.)
Protection type : Shut down o/p voltage, re-power on to recover
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
CIRCUIT BREAKER
20A
10A
GFCI PROCTECTION
Optional (Only type F)
None
WORKING TEMP.
Note.3 0 ~ +40 @ 100% load ; 60 @ 50% load
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT
STORAGE TEMP., HUMIDITY -30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH
VIBRATION
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL458 (only for "GFCI" receptacle-Type F ) None
SAFETY & LVD
WITHSTAND VOLTAGE
EMC
EMC EMISSION
None
Bat I/P - AC I/P:3.0KVAC Bat I/P - AC O/P:3.0KVAC
Compliance to FCC class A
EN60950-1
AC O/P - FG:1.5KVAC
Compliance to EN55022 class B, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
EMC IMMUNITY
None
Compliance to EN61000-4-2,3,4,5,6,8,11
AC
CHARGE CURRENT (Typ.) 5.5A
CHARGER CHARGE VOLTAGE
14.3V 4%
2.7A
28.5V 4%
1.35A
57V 4%
5.5A
14.3V 4%
2.7A
28.5V 4%
1.35A
57V 4%
MAX OPEN CIRCUIT VOLTAGE 25V
SOLAR CHARGE CURRENT (max.) 30A
CHARGER
CHARGE VOLTAGE
14.3V 4%
45V
28.5V 4%
75V
57V 4%
25V
14.3V 4%
45V
28.5V 4%
75V
57V 4%
CONTROL WIRING
RJ11 -RS232 (Option)
OTHERS DIMENSION
420*220*88mm (L*W*H)
PACKING
6.85Kg; 2pcs/14.7Kg/1.61CUFT
NOTE
1.Output derating capacity referenced by curve 1.
2.THD and Efficiency is tested by 1000W, linear load at 13V, 26V, 52V input voltage.
3.Output derating capacity referenced by curve 2.
4.All parameters not specified above are measured at rated load, 25 of ambient temperature.
5.DC current is tested by 1500W, linear load at 13V, 26V, 52V input voltage.
File Name:TN-1500-SPEC 2012-02-21