English
Language : 

SUS01 Datasheet, PDF (1/1 Pages) Mean Well Enterprises Co., Ltd. – 1W DC-DC Unregulated Single Output Converter
1W DC-DC Unregulated Single Output Converter
SUS01 series
Features :
1000VDC I/O isolation
Internal SMD technology
Built-in EMI filter
Cooling by free air convection
Non-conductive plastic case
Dual in line package
SIP packge is available
100% burn-in test
Low cost / High reliability
2 years warranty
SELECTION GUIDE
ORDER NO.
DC OUTPUT VOLTAGE
OUTPUT CURRENT RANGE
EFFICIENCY
SUS01L-05
5V
0 ~ 200mA
73%
SUS01M-05 SUS01N-05
74%
72%
SUS01O-05
74%
SUS01L-09
9V
0 ~ 111mA
75%
SUS01M-09 SUS01N-09
79%
80%
SUS01O-09
77%
ORDER NO.
SUS01L-12 SUS01M-12 SUS01N-12 SUS01O-12 SUS01L-15 SUS01M-15
DC OUTPUT VOLTAGE
12V
15V
OUTPUT CURRENT RANGE 0 ~ 84mA
0 ~ 67mA
EFFICIENCY
78%
82%
83%
83%
79%
82%
SPECIFICATION
RATED POWER
1W
RIPPLE & NOISE (max.) Note.2 100mVp-p
LINE REGULATION Note.3 1.2% for 1% input variation
OUTPUT
LOAD REGULATION Note.4 8.0%
VOLTAGE ACCURACY
2.0%
SWITCHING FREQUENCY 50KHz min.
VOLTAGE RANGE
4.5 ~ 5.5V 10.8 ~ 13.2V 21.6 ~ 26.4V 43.2 ~ 52.8V 4.5 ~ 5.5V 10.8 ~ 13.2V
NORMAL VOLTAGE
5V
12V
24V
48V
5V
12V
INPUT
Full load 280mA
INPUT CURRENT
No load 21mA
112mA
11mA
55mA
10mA
28mA
3mA
280mA
21mA
112mA
11mA
FILTER
Capacitor type
PROTECTION
Fuse recommended
OVERLOAD
PROTECTION
SHORT CIRCUIT
Momentary
Protection type : Broken
Momentary
Protection type : Broken
WORKING TEMP.
-25 ~ +71 (Refer to output load derating curve)
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -25 ~ +105 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03% / (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
ISOLATION CAPACITANCE
I/P-O/P:1KVDC
I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH
80pF max.
MTBF
700khrs min. MIL-HDBK-217F(25 )
OTHERS DIMENSION
22.6*9.9*8.4mm or 0.89"*0.39"*0.33" inch (L*W*H)
WEIGHT
3.1g
SUS01N-15
83%
21.6 ~ 26.4V
24V
55mA
10mA
SUS01O-15
83%
43.2 ~ 52.8V
48V
28mA
3mA
Mechanical Specification
Unit: mm (inch)
9.9 (0.39)
0.5 (0.02)
3.81 (0.15)
16 1
BOTTOM
VIEW
11 6
10 7
98
2.54 (0.10)
7.62 (0.30)
8.4 (0.33)
Pin Configuration
Pin No.
1 & 16
6 & 11
7 & 10
8&9
Output
+Vin
-Vout
+Vout
-Vin
Derating Curve
100
80
-25
0
25 50 60 71 100
Ta ( )
NOTE
1.All parameters are specified at normal input, rated load, 25 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 20% to 100% rated load.
File Name: SUS01-SPEC 2008-05-08