English
Language : 

SPV-300_10 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 300W Single Output with PFC Function
300W Single Output with PFC Function
SPV-300 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC Fan
Output voltage programmable from 20~110% by 1~5.5VDC external
control signal
Built-in remote ON-OFF control
Built-in fan speed control
Fixed switching frequency at 100KHz
3 years warranty
SPECIFICATION
MODEL
SPV-300-12
SPV-300-24
SPV-300-48
DC VOLTAGE
12V
24V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
25A
0 ~ 25A
300W
12.5A
0 ~ 12.5A
300W
6.25A
0 ~ 6.25A
300W
OUTPUT
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE
10.8 ~ 13.2V
VOLTAGE TOLERANCE Note.3 1.0%
LINE REGULATION
0.3%
LOAD REGULATION
0.5%
150mVp-p
20 ~ 26.4V
1.0%
0.2%
0.5%
240mVp-p
41 ~ 52.8V
1.0%
0.2%
0.5%
SETUP, RISE TIME
800ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load
INPUT
VOLTAGE RANGE Note.5 88 ~ 264VAC 124 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC PF>0.98/115VAC at full load
EFFICIENCY (Typ.)
83.5%
85%
AC CURRENT (Typ.)
5A/115VAC 2.5A/230VAC
INRUSH CURRENT (Typ.) 20A/115VAC 40A/230VAC
86.5%
LEAKAGE CURRENT
<1mA / 240VAC
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
13.8 ~ 16.2V
27.6 ~ 32.4V
57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
80 5 (TSW1 : detect on heatsink of power transistor)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
REMOTE CONTROL
FUNCTION
OUTPUT VOLTAGE TRIM
4 ~ 10VDC power off, <0 ~ 0.8VDC power on
2.4 ~ 13.2V
4.8 ~ 26.4V
WORKING TEMP.
-20 ~ +65 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT
STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
9.6 ~ 52.8V
SAFETY
EMC
(Note 4)
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
MTBF
OTHERS
DIMENSION
207K hrs min. MIL-HDBK-217F (25 )
215*115*50mm (L*W*H)
NOTE
PACKING
1.1Kg; 12pcs/14Kg/0.92CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:SPV-300-SPEC 2010-10-18