Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload/ Over voltage / Over temperature
Forced air cooling by built-in DC fan
Built-in cooling Fan ON-OFF control
Built-in remote ON-OFF control
Built-in remote sense function
3 years warranty
SPECIFICATION
( for 24V only)
MODEL
SP-500-12
SP-500-13.5
SP-500-15
SP-500-24
SP-500-27
SP-500-48
OUTPUT
INPUT
DC VOLTAGE
12V
13.5V
15V
RATED CURRENT
40A
36A
32A
CURRENT RANGE
0 ~ 40A
0 ~ 36A
0 ~ 32A
RATED POWER
480W
486W
480W
RIPPLE & NOISE (max.) Note.2 240mVp-p
240mVp-p
240mVp-p
VOLTAGE ADJ. RANGE
10 ~ 13.2V
12 ~ 15V
13.5 ~ 18V
VOLTAGE TOLERANCE Note.3 1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
LOAD REGULATION
0.5%
0.5%
0.5%
SETUP, RISE TIME
1500ms, 50ms at full load
HOLD UP TIME (Typ.)
24ms at full load
VOLTAGE RANGE Note.5 88 ~ 264VAC 124 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC PF>0.95/115VAC at full load
EFFICIENCY(Typ.)
84%
84%
83%
AC CURRENT (Typ.)
7A/115VAC 3.5A/230VAC
INRUSH CURRENT (Typ.) 18A/115VAC 36A/230VAC
24V
20A
0 ~ 20A
480W
240mVp-p
20 ~ 26.4V
1.0%
0.5%
0.5%
85.5%
27V
18A
0 ~ 18A
486W
200mVp-p
24 ~ 30V
1.0%
0.5%
0.5%
86.5%
48V
10A
0 ~ 10A
480W
300mVp-p
41 ~ 56V
1.0%
0.5%
0.5%
87%
LEAKAGE CURRENT
<3.5mA/240VAC
OVERLOAD
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
PROTECTION
OVER VOLTAGE
FAN CONTROL, O.T.P.
13.8 ~ 16.2V
15.5 ~ 18.2V
18 ~ 21V
27.6 ~ 32.4V
31 ~ 36.5V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
RTH1 or RTH2 50 FAN ON, 45 FAN OFF, 70 output shutdown
57.6 ~ 67.2V
FUNCTION REMOTE CONTROL
RC+/RC-: Short = power on ; Open = power off
WORKING TEMP.
-10 ~ +50 (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1, CCC GB4943( for 24V only) approved
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note 4) EMC EMISSION
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
MTBF
133.4K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
170*120*93mm (L*W*H)
PACKING
1.9Kg; 8pcs/15.5Kg/1.06CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.