English
Language : 

SE-600 Datasheet, PDF (1/2 Pages) Total Power International – 600W Single Output Power Supply
600W Single Output Power Supply
SE-600 series
Features :
AC input active surge current limiting
AC input range selected by switch
Protections:Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC fan
High power density 4.9w/in3
Built-in remote sense function
UL approved
Low cost
2 years warranty
SPECIFICATION
MODEL
SE-600-5
SE-600-12
SE-600-15
SE-600-24
SE-600-27
SE-600-36
SE-600-48
DC VOLTAGE
5V
12V
15V
24V
27V
36V
48V
RATED CURRENT
100A
50A
40A
25A
22.2A
16.6A
12.5A
CURRENT RANGE
0 ~ 100A
0 ~ 50A
0 ~ 40A
0 ~ 25A
0 ~ 22.2A
0 ~ 16.6A
0 ~ 12.5A
RATED POWER
500W
600W
600W
600W
599.4W
597.6W
600W
OUTPUT
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE
4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
0.5%
150mVp-p
10 ~ 13.5V
1.0%
0.5%
150mVp-p
13.5 ~ 16.5V
1.0%
0.5%
150mVp-p
22 ~ 26.4V
1.0%
0.5%
150mVp-p
24 ~ 30V
1.0%
0.5%
200mVp-p
32 ~ 40V
1.0%
0.5%
200mVp-p
43 ~ 56V
1.0%
0.5%
LOAD REGULATION
2.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME
1000ms, 50ms/230VAC 1000ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
20ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE
90 ~ 132VAC / 180 ~ 264VAC selected by switch 254 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
78%
83%
84%
87%
87%
87%
88%
INPUT
AC CURRENT (Typ.)
12A/115VAC 7.5A/230VAC
INRUSH CURRENT (Typ.) 25A/115VAC 50A/230VAC
LEAKAGE CURRENT
<2.0mA / 240VAC
OVERLOAD
105 ~ 125% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
5.75 ~ 6.3V
13.8 ~ 16.2V 18 ~ 21V
27.6 ~ 32.4V 31 ~ 36.5V
Protection type : Shut down o/p voltage, re-power on to recover
85 5 (TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
42 ~ 50V
57.6 ~ 67.2V
WORKING TEMP.
-20 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.05%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
SAFETY &
WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
UL60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
MTBF
197K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
247*127*63.5mm (L*W*H)
PACKING
2.1Kg; 6pcs/13.4Kg/1.03CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
File Name:SE-600-SPEC 2008-04-10