English
Language : 

SE-200_12 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 200W Single Output Switching Power Supply
200W Single Output Switching Power Supply
SE-200 series
Features :
AC input range selectable by switch
Protections: Short circuit / Overload / Over voltage/
Over temperature
Cooling by free air convection
Withstand 300vac surge input for 5 second
Built-in constant current limiting circuit
100% full load burn-in test
LED indicator for power on
Fixed switching frequency at 90KHz
Low cost,high reliability
2 years warranty
SPECIFICATION
MODEL
SE-200-3.3 SE-200-5 SE-200-7.5 SE-200-12 SE-200-15 SE-200-24 SE-200-27 SE-200-36 SE-200-48
OUTPUT
DC VOLTAGE
3.3V
RATED CURRENT
40A
CURRENT RANGE
0 ~ 40A
RATED POWER
132W
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE
2.97 ~ 3.7V
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
0.5%
LOAD REGULATION
1.5%
5V
40A
0 ~ 40A
200W
150mVp-p
4.5 ~ 5.6V
2.0%
0.5%
1.0%
7.5V
27A
0 ~ 27A
202.5W
150mVp-p
6 ~ 9V
2.0%
0.5%
1.0%
12V
17A
0 ~ 17A
204W
150mVp-p
10 ~ 13.5V
1.0%
0.5%
0.5%
15V
14A
0 ~ 14A
210W
150mVp-p
13.5 ~ 18V
1.0%
0.5%
0.5%
24V
8.8A
0 ~ 8.8A
211.2W
150mVp-p
20 ~ 26.4V
1.0%
0.5%
0.5%
27V
7.8A
0 ~ 7.8A
210.6W
200mVp-p
26 ~ 32V
1.0%
0.5%
0.5%
36V
5.9A
0 ~ 5.9A
212.4W
240mVp-p
32 ~ 40V
1.0%
0.5%
0.5%
48V
4.4A
0 ~ 4.4A
211.2W
240mVp-p
41 ~ 56V
1.0%
0.5%
0.5%
SETUP, RISE TIME
1000ms, 50ms/230VAC 1000ms,50ms/115VAC at full load
HOLD UP TIME
VOLTAGE RANGE Note.4
20ms/230VAC 16ms/115VAC at full load
90 ~ 132VAC / 180 ~ 264VAC by switch 254 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
AC CURRENT
75%
79%
82%
85%
85%
87%
88%
89%
89%
4.5A/115VAC 2.5A/230VAC
INRUSH CURRENT (max.) 40A/115VAC 55A/230VAC
LEAKAGE CURRENT
<3.5mA / 240VAC
OVER LOAD
PROTECTION OVER VOLTAGE
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
3.8 ~ 4.9V 5.75 ~ 7.0V 9.4 ~ 10.9V 13.8 ~ 16.2V 18 ~ 21V 27.6 ~ 32.4V 33.7 ~ 39.2V 41.4 ~ 46.8V 57.6 ~ 67.2V
Protection type :Shut down O/P voltage, re-power on to recover
OVER TEMPERATURE
95 5 (3.3V);100 5 (5V); 90 5 (7.5V);85 5 (12~24V);80 5 (27~36V);75 5 (48V) (TSW1) Detect on case
Protection type : Shut down O/P voltage, recovers automatically after temperature goes down
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY WITHSTAND VOLTAGE
-20 ~ +50 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
OTHERS
ISOLATION RESISTANCE
MTBF
DIMENSION
PACKING
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25
271.9K hrs min. MIL-HDBK-217F (25 )
215*115*50mm (L*W*H)
0.93Kg; 12pcs/12Kg/0.92CUFT
/ 70% RH
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please connect positive pole of input voltage with mark “N” of terminal block, connect negative pole of input voltage
with mark “L” of terminal block, using DC voltage for input voltage.
File Name:SE-200-SPEC 2012-02-28