English
Language : 

SD-100 Datasheet, PDF (1/2 Pages) Astrodyne Corporation – 100W Single Output DC-DC Converter
100W Single Output DC-DC Converter
SD-100 series
Features :
2:1 wide input range
Protections: Short circuit / Overload / Over voltage
1500VDC I/O isolation
Built-in EMI filter, low ripple noise
100% full load burn-in test
Fixed switching frequency at 83KHz
24V and 48V input voltage design refer to LVD
Low cost
High reliability
1 year warranty
SPECIFICATION
(for D type only)
MODEL
SD-100B-5 SD-100C-5 SD-100D-5 SD-100B-12 SD-100C-12 SD-100D-12 SD-100B-24 SD-100C-24 SD-100D-24
DC VOLTAGE
5V
12V
24V
RATED CURRENT
20A
8.5A
4.2A
CURRENT RANGE
0 ~ 20A
0 ~ 8.5A
0 ~ 4.2A
RATED POWER
100W
102W
100.8W
OUTPUT
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE ADJ. RANGE
4.5 ~ 5.5VDC
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
0.5%
120mVp-p
11 ~ 16VDC
1.0%
0.3%
150mVp-p
23 ~ 30VDC
1.0%
0.2%
LOAD REGULATION
0.5%
0.3%
0.2%
SETUP, RISE TIME
2s, 50ms(only D mode) at full load
HOLD UP TIME (Typ.)
20ms(only D mode) at full load
INPUT
VOLTAGE RANGE
EFFICIENCY (Typ.)
DC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
B:19 ~ 36VDC C:36 ~ 72VDC D:72 ~ 144VDC or 85 ~ 132VAC
74%
75%
76%
75%
77%
80%
4.8A/24V 2.4A/48V 1.8A/96V 4.8A/24V 2.4A/48V 1.8A/96V
D:18A/96VDC
78%
4.8A/24V
81%
2.4A/48V
83%
1.8A/96V
LEAKAGE CURRENT
<0.75mA/120VAC(SD-100D)
OVERLOAD
PROTECTION
OVER VOLTAGE
105 ~ 135% rated output power
Protection type : Fold back current limiting, recovers automatically after fault condition is removed
5.75 ~ 6.75V/10% load
16.8 ~ 20V/10% load
31.5 ~ 37.5V/10% load
Protection type : Hiccup mode, recovers automatically after fault condition is removed
WORKING TEMP.
-10 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
IEC60950-1 CB approved by TUV (for D type only)
SAFETY & WITHSTAND VOLTAGE
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
EMC
(Note 4)
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
OTHERS
NOTE
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,6,8; ENV50204, light industry level, criteria A
MTBF
356.7K hrs min.(SD-100B) 355.5K hrs min.(SD-100C) 341.9K Hrs min.(SD-100D) MIL-HDBK-217F (25 )
DIMENSION
199*98*38mm (L*W*H)
PACKING
0.65Kg; 20pcs/13.8Kg/0.8CUFT
1. All parameters NOT specially mentioned are measured at 24,48,96VDC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:SD-100-SPEC 2008-08-29