800W Single Output With Parallel Function
SCN-800 series
Features :
AC input range selected by switch
Protections: Short circuit / Overload / Over voltage / Over temp.
High reliability/ Low ripple noise
Built-in remote sense function
Built-in remote ON-OFF control
Built-in parallel operation function
Can adjust from 20~100% output voltage by external control 1-5V
Forced air cooling by built-in DC fan
Case coating with paint
2 years warranty
SPECIFICATION
ORDER NO.
SCN-800-12
SCN-800-15
SCN-800-24
SCN-800-48
SAFETY MODEL NO.
800S-N012
800S-N015
800S-N024
800S-N048
DC VOLTAGE
12V
15V
24V
48V
RATED CURRENT
66A
54A
33A
16.6A
CURRENT RANGE
0 ~ 66A
0 ~ 54A
0 ~ 33A
0 ~ 16.6A
OUTPUT
RATED POWER
792W
810W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
VOLTAGE ADJ. RANGE
5.0% typical adjustment by potentiometer
VOLTAGE TOLERANCE Note.3 1.0%
1.0%
LINE REGULATION
0.5%
0.5%
792W
796W
240mVp-p
480mVp-p
20~100% adjustment by 1~5VDC external control
1.0%
1.0%
0.5%
0.5%
LOAD REGULATION
0.5%
0.5%
0.5%
0.5%
SETUP, RISE, HOLD UP TIME 800ms, 50ms, 16ms at full load
VOLTAGE RANGE
90 ~ 130VAC / 180 ~ 260VAC selected by switch, 260 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
80%
81%
85%
87%
INPUT
AC CURRENT
17A / 115VAC 9A / 230VAC
INRUSH CURRENT (max.) 60A / 230VAC
LEAKAGE CURRENT (max.) 3.5mA / 240VAC
OVERLOAD
110 ~ 135% rated output power
Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover
PROTECTION OVER VOLTAGE
110 ~ 135% follow to output set up point
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
WORKING TEMP.
>100 / measure by heat sink, near transformer
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +65 (Refer to output load derating curve)
WORKING TEMP., HUMIDITY 20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
0.04% / (0 ~ 50 )
10 ~ 200Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY &
EMC
(Note. 4)
OTHERS
SAFETY STANDARDS
Design refer to UL1950, CSA22.2, IEC60950
WITHSTAND VOLTAGE
I/P-O/P, I/P-FG:1500VAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, >100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Design refer to FCC part 15 class A
HARMONIC CURRENT
----
EMS IMMUNITY
----
MTBF
120khrs min. MIL-HDBK-217F (25 )
DIMENSION
291*132*68mm (L*W*H)
PACKING
2.3kg; 8pcs/ 24kg /CARTON
SPECIAL FUNCTION
DC voltage adj., Remote sensing, remote control, parallel operation (refer to terminal instruction manual)
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.Tolerence: includes set up tolerance, line regulation, load regulation.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:SCN-800-SPEC 2007-11-01