SPECIFICATION
ORDER NO.
SCN-600-05
SCN-600-12
SCN-600-15
SCN-600-18
SCN-600-24
SCN-600-48
OUTPUT
SAFETY MODEL NO.
600S-N005
600S-N012
600S-N015
600S-N018
600S-N024
DC VOLTAGE
5V
12V
15V
18V
24V
RATED CURRENT
100A
50A
40A
33A
25A
CURRENT RANGE
0 ~ 100A
0 ~ 50A
0 ~ 40A
0 ~ 33A
0 ~ 25A
RATED POWER
500W
600W
600W
594W
600W
RIPPLE & NOISE (max.) Note.2 100mVp-p
120mVp-p
150mVp-p
180mVp-p
240mVp-p
VOLTAGE ADJ. RANGE
5.0% typical adjustment by potentiometer 20~100% adjustment by 1~5VDC external control
VOLTAGE TOLERANCE Note.3 1.5%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
1.0%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE, HOLD UP TIME 800ms, 50ms, 16ms at full load
600S-N048
48V
12A
0 ~ 12A
576W
480mVp-p
1.0%
0.5%
0.5%
VOLTAGE RANGE
90 ~ 130VAC / 180 ~ 260VAC selected by switch, 260 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
77%
80%
81%
82%
85%
87%
INPUT
AC CURRENT
11A / 115VAC 7.0A / 230VAC
INRUSH CURRENT (max.) 60A / 230VAC
LEAKAGE CURRENT
3.5mA / 240VAC
OVERLOAD
101 ~ 115%
110 ~ 135% rated output power
Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover
PROTECTION OVER VOLTAGE
110 ~ 135% follow to output set up point
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
>100 / measure by heat sink, near transformer
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-10 ~ +65 (Refer to output load derating curve)
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.04% / (0 ~ 50 )
VIBRATION
10 ~ 200Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, CSA22.2, IEC60950 approved
SAFETY &
EMC
(Note. 4)
WITHSTAND VOLTAGE
I/P-O/P, I/P-FG:1500VAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, 100M Ohms / 500VDC / 25
EMI CONDUCTION & RADIATION Compliance to FCC part 15 class A
HARMONIC CURRENT
----
/ 70% RH
EMS IMMUNITY
----
OTHERS
MTBF
DIMENSION
PACKING
SPECIAL FUNCTION
120Khrs min. MIL-HDBK-217F (25 )
291*132*68mm (L*W*H)
2.6kg; 8pcs/ 24kg/ CARTON
DC voltage adj., Remote sensing, remote control, parallel operation (refer to terminal instruction manual)
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.Tolerence: includes set up tolerance, line regulation, load regulation.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:SCN-600-SPEC 2008-05-06