English
Language : 

SCN-2K0 Datasheet, PDF (1/4 Pages) Mean Well Enterprises Co., Ltd. – 2000W Single Output With Parallel Function
2000W Single Output With Parallel Function
SCN-2K0 series
■ Features :
AC input 200~260VAC,3ψ 3wires(other system available)
Protections: Short circuit / Overload / Over voltage / Over temp.
High reliability; Low ripple noise
Built-in remote sense function
Built-in remote ON-OFF control
Built-in parallel operation function
Can adjust from 20~100% output voltage by external control 1-5V
Forced air cooling by built-in DC fan
Case coating with paint
2 years warranty
SPECIFICATION
ORDER NO.
SCN-2K0-05
SCN-2K0-12
SCN-2K0-15
SCN-2K0-24
SCN-2K0-48
OUTPUT
SAFETY MODEL NO.
2K0S-N005
2K0S-N012
DC VOLTAGE
5V
12V
RATED CURRENT
250A
167A
CURRENT RANGE
0 ~ 250A
0 ~ 167A
RATED POWER
1250W
2004W
RIPPLE & NOISE (max.) Note.2 150mVp-p
180mVp-p
VOLTAGE ADJ. RANGE
± 5.0% typical adjustment by potentiometer
VOLTAGE TOLERANCE Note.3 ± 3.0%
± 2.0%
LINE REGULATION
± 0.5%
± 0.5%
LOAD REGULATION
± 2.5%
± 1.5%
SETUP, RISE, HOLD UP TIME 800ms, 50ms, 16ms at full load
2K0S-N015
2K0S-N024
15V
24V
134A
83.5A
0 ~ 134A
0 ~ 83.5A
2010W
2004W
200mVp-p
240mVp-p
20~100% adjustment by 1~5VDC external control
± 2.0%
± 1.0%
± 0.5%
± 0.5%
± 1.5%
± 0.5%
2K0S-N048
48V
42A
0 ~ 42A
2016W
480mVp-p
± 1.0%
± 0.5%
± 0.5%
VOLTAGE RANGE
200 ~ 260VAC, 3ψ , 3wires
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
78%
84%
84%
85%
86%
INPUT
AC CURRENT
10A / 230VAC
INRUSH CURRENT (max.) 120A / 230VAC
LEAKAGE CURRENT (max.) 5mA/ 240VAC
OVERLOAD
110 ~ 135% rated output power
Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover
PROTECTION OVER VOLTAGE
110 ~ 135% follow to output set up point
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
>100℃ / measure by heat sink, near transformer
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-10 ~ +65℃(Refer to output load derating curve)
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
VIBRATION
± 0.04% / ℃ (0 ~ 50℃)
10 ~ 200Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
Design refer to UL1950, CSA22.2, IEC60950
SAFETY &
EMC
(Note. 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:1500VAC, I/P-FG:1500VAC
I/P-O/P, I/P-FG, >100M Ohms / 500VDC / 25℃/ 70% RH
Design refer to FCC part 15 class A
----
EMS IMMUNITY
MTBF
----
30khrs min. MIL-HDBK-217F (25℃)
DIMENSION
OTHERS
PACKING
320*212*134mm (L*W*H)
9.0kg; 1pcs/ 10kg / CARTON
SPECIAL FUNCTION
DC voltage adj., Remote sensing, remote control, parallel operation (refer to terminal instruction manual)
NOTE
1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
2.Tolerence: includes set up tolerance, line regulation, load regulation.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:SCN-2K0-SPEC 2007-11-01