English
Language : 

SCN-1K2 Datasheet, PDF (1/3 Pages) Astrodyne Corporation – 1200W With Parallel Function
1200W Single Output With Parallel Function
SCN-1K2 series
Features :
AC input 200~260V only
Protections: Short circuit / Overload / Over voltage / Over temp.
High reliability/ Low ripple noise
Built-in remote sense function
Built-in remote ON-OFF control
Built-in parallel operation function
Can adjust from 20~100% output voltage by external control 1-5V
Forced air cooling by built-in DC fan
Case coating with paint
2 years warranty
SPECIFICATION
ORDER NO.
SCN-1K2-05
SCN-1K2-12
SCN-1K2-15
SCN-1K2-24
SCN-1K2-48
OUTPUT
SAFETY MODEL NO.
1K2S-N005
1K2S-N012
DC VOLTAGE
5V
12V
RATED CURRENT
180A
100A
CURRENT RANGE
0 ~ 180A
0 ~ 100A
RATED POWER
900W
1200W
RIPPLE & NOISE (max.) Note.2 100mVp-p
120mVp-p
VOLTAGE ADJ. RANGE
5.0% typical adjustment by potentiometer
VOLTAGE TOLERANCE Note.3 2.5%
1.0%
LINE REGULATION
0.5%
0.5%
LOAD REGULATION
2.0%
0.5%
SETUP, RISE, HOLD UP TIME 800ms, 50ms, 16ms at full load
1K2S-N015
1K2S-N024
15V
24V
80A
50A
0 ~ 80A
0 ~ 50A
1200W
1200W
150mVp-p
240mVp-p
20 ~ 100% adjustment by 1 ~ 5VDC external control
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
1K2S-N048
48V
24A
0 ~ 24A
1152W
480mVp-p
1.0%
0.5%
0.5%
VOLTAGE RANGE
200 ~ 260VAC 290 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
77%
83%
85%
85%
87%
INPUT
AC CURRENT
11A / 230VAC
INRUSH CURRENT (max.) 120A / 230VAC
LEAKAGE CURRENT (max.) 3.5mA / 240VAC
OVERLOAD
101 ~ 115%
110 ~ 135% rated output power
Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover
PROTECTION OVER VOLTAGE
110 ~ 135% follow to output set up point
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
>100 / measure by heat sink, near transformer
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-10 ~ +65 (Refer to output load derating curve)
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.04% / (0 ~ 50 )
VIBRATION
10 ~ 200Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, CSA22.2, IEC60950 approved
SAFETY &
EMC
(Note. 4)
WITHSTAND VOLTAGE
I/P-O/P, I/P-FG :1500VAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, >100M Ohms / 500VDC / 25
EMI CONDUCTION & RADIATION Compliance to FCC part 15 class A
HARMONIC CURRENT
----
/ 70% RH
EMS IMMUNITY
----
MTBF
60Khrs min. MIL-HDBK-217F (25 )
OTHERS
DIMENSION
PACKING
SPECIAL FUNCTION
291*132*132mm (L*W*H)
4.75kg ; 4pcs/20kg/CARTON
DC voltage adj., Remote sensing, remote control, parallel operation (refer to terminal instruction manual)
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.Tolerence: includes set up tolerance, line regulation, load regulation.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:SCN-1K2-SPEC 2008-05-06